This patch fix bug related to checking fully charged state of battery
when charger-manager call is_full_charged() function. After reading
property of charger/fuel-gauge through power_supply API, val.intval is
more than 1. So, is_full_charged() function always return true. If true,
battery means fully charged state.

Signed-off-by: Chanwoo Choi <cw00.c...@samsung.com>
Signed-off-by: Myungjoo Ham <myungjoo....@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.p...@samsung.com>
---
 drivers/power/charger-manager.c |   33 +++++++++++++--------------------
 1 files changed, 13 insertions(+), 20 deletions(-)

diff --git a/drivers/power/charger-manager.c b/drivers/power/charger-manager.c
index 8a0aca6..ee039b9 100644
--- a/drivers/power/charger-manager.c
+++ b/drivers/power/charger-manager.c
@@ -239,44 +239,37 @@ static bool is_full_charged(struct charger_manager *cm)
        int uV;
 
        /* If there is no battery, it cannot be charged */
-       if (!is_batt_present(cm)) {
-               val.intval = 0;
-               goto out;
-       }
+       if (!is_batt_present(cm))
+               return false;
 
        if (cm->fuel_gauge && desc->fullbatt_full_capacity > 0) {
+               val.intval = 0;
+
                /* Not full if capacity of fuel gauge isn't full */
                ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
                                POWER_SUPPLY_PROP_CHARGE_FULL, &val);
-               if (!ret && val.intval > desc->fullbatt_full_capacity) {
-                       val.intval = 1;
-                       goto out;
-               }
+               if (!ret && val.intval > desc->fullbatt_full_capacity)
+                       return true;
        }
 
        /* Full, if it's over the fullbatt voltage */
        if (desc->fullbatt_uV > 0) {
                ret = get_batt_uV(cm, &uV);
-               if (!ret && uV >= desc->fullbatt_uV) {
-                       val.intval = 1;
-                       goto out;
-               }
+               if (!ret && uV >= desc->fullbatt_uV)
+                       return true;
        }
 
        /* Full, if the capacity is more than fullbatt_soc */
        if (cm->fuel_gauge && desc->fullbatt_soc > 0) {
+               val.intval = 0;
+
                ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
                                POWER_SUPPLY_PROP_CAPACITY, &val);
-               if (!ret && val.intval >= desc->fullbatt_soc) {
-                       val.intval = 1;
-                       goto out;
-               }
+               if (!ret && val.intval >= desc->fullbatt_soc)
+                       return true;
        }
 
-       val.intval = 0;
-
-out:
-       return val.intval ? true : false;
+       return false;
 }
 
 /**
-- 
1.7.0.4

--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majord...@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html
Please read the FAQ at  http://www.tux.org/lkml/

Reply via email to