On Fri, Nov 09, 2012 at 02:33:51PM -0700, Stephen Warren wrote:
> On 11/09/2012 06:22 AM, Thierry Reding wrote:
> > On Fri, Nov 09, 2012 at 01:56:55PM +0100, Thierry Reding wrote:
> >> The Harmony board has an Analog Devices ADT7461 temperature
> >> sensor connected to the DVC bus. It can be used to monitor the
> >> ambient (local) and on-die (remote) temperatures.
> > 
> > Note that I haven't actually tested this, as I no longer have
> > access to Harmony hardware. Testing can easily be done either by
> > reading the files from sysfs directly or by running the sensors
> > utility from the lm-sensors package.
> 
> Tested-by: Stephen Warren <swar...@nvidia.com>
> 
> Ventana also has the same sensor and due to git am applying your patch
> to the wrong file (I've renamed all my .dts files), I ended up testing
> that too, so you may as well send a second patch for Ventana. Ventana
> has an nct1008 though.

Okay, will do. Thanks for testing.

Thierry