Currently the naming of a cooling device is just a cooling technique followed by a number. When there are multiple cooling devices using the same technique, it is impossible to clearly identify the related device as this one is just a number.
For instance: thermal-cpufreq-0 thermal-cpufreq-1 etc ... The 'thermal' prefix is redundant with the subsystem namespace. This patch removes the 'thermal prefix and changes the number by the device name. So the naming above becomes: cpufreq-cpu0 cpufreq-cpu4 etc ... Signed-off-by: Daniel Lezcano <daniel.lezc...@linaro.org> --- drivers/thermal/cpufreq_cooling.c | 28 +++++++--------------------- 1 file changed, 7 insertions(+), 21 deletions(-) diff --git a/drivers/thermal/cpufreq_cooling.c b/drivers/thermal/cpufreq_cooling.c index 10af3341e5ea..cf0332bbdcd3 100644 --- a/drivers/thermal/cpufreq_cooling.c +++ b/drivers/thermal/cpufreq_cooling.c @@ -13,6 +13,7 @@ #include <linux/cpu.h> #include <linux/cpufreq.h> #include <linux/cpu_cooling.h> +#include <linux/device.h> #include <linux/energy_model.h> #include <linux/err.h> #include <linux/export.h> @@ -50,8 +51,6 @@ struct time_in_idle { /** * struct cpufreq_cooling_device - data for cooling device with cpufreq - * @id: unique integer value corresponding to each cpufreq_cooling_device - * registered. * @last_load: load measured by the latest call to cpufreq_get_requested_power() * @cpufreq_state: integer value representing the current state of cpufreq * cooling devices. @@ -69,7 +68,6 @@ struct time_in_idle { * cpufreq_cooling_device. */ struct cpufreq_cooling_device { - int id; u32 last_load; unsigned int cpufreq_state; unsigned int max_level; @@ -82,7 +80,6 @@ struct cpufreq_cooling_device { struct freq_qos_request qos_req; }; -static DEFINE_IDA(cpufreq_ida); static DEFINE_MUTEX(cooling_list_lock); static LIST_HEAD(cpufreq_cdev_list); @@ -528,11 +525,11 @@ __cpufreq_cooling_register(struct device_node *np, { struct thermal_cooling_device *cdev; struct cpufreq_cooling_device *cpufreq_cdev; - char dev_name[THERMAL_NAME_LENGTH]; unsigned int i; struct device *dev; int ret; struct thermal_cooling_device_ops *cooling_ops; + char name[THERMAL_NAME_LENGTH]; dev = get_cpu_device(policy->cpu); if (unlikely(!dev)) { @@ -567,16 +564,6 @@ __cpufreq_cooling_register(struct device_node *np, /* max_level is an index, not a counter */ cpufreq_cdev->max_level = i - 1; - ret = ida_simple_get(&cpufreq_ida, 0, 0, GFP_KERNEL); - if (ret < 0) { - cdev = ERR_PTR(ret); - goto free_idle_time; - } - cpufreq_cdev->id = ret; - - snprintf(dev_name, sizeof(dev_name), "thermal-cpufreq-%d", - cpufreq_cdev->id); - cooling_ops = &cpufreq_cooling_ops; #ifdef CONFIG_THERMAL_GOV_POWER_ALLOCATOR @@ -591,7 +578,7 @@ __cpufreq_cooling_register(struct device_node *np, pr_err("%s: unsorted frequency tables are not supported\n", __func__); cdev = ERR_PTR(-EINVAL); - goto remove_ida; + goto free_idle_time; } ret = freq_qos_add_request(&policy->constraints, @@ -601,10 +588,12 @@ __cpufreq_cooling_register(struct device_node *np, pr_err("%s: Failed to add freq constraint (%d)\n", __func__, ret); cdev = ERR_PTR(ret); - goto remove_ida; + goto free_idle_time; } - cdev = thermal_of_cooling_device_register(np, dev_name, cpufreq_cdev, + snprintf(name, sizeof(name), "cpufreq-%s", dev_name(dev)); + + cdev = thermal_of_cooling_device_register(np, name, cpufreq_cdev, cooling_ops); if (IS_ERR(cdev)) goto remove_qos_req; @@ -617,8 +606,6 @@ __cpufreq_cooling_register(struct device_node *np, remove_qos_req: freq_qos_remove_request(&cpufreq_cdev->qos_req); -remove_ida: - ida_simple_remove(&cpufreq_ida, cpufreq_cdev->id); free_idle_time: free_idle_time(cpufreq_cdev); free_cdev: @@ -712,7 +699,6 @@ void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev) thermal_cooling_device_unregister(cdev); freq_qos_remove_request(&cpufreq_cdev->qos_req); - ida_simple_remove(&cpufreq_ida, cpufreq_cdev->id); free_idle_time(cpufreq_cdev); kfree(cpufreq_cdev); } -- 2.17.1