From: Parav Pandit <[email protected]>
[ Upstream commit 0e22bfb7c046e7c8ae339f396e78a0976633698c ]
rate_bytes_ps is a 64-bit field. It passed as 32-bit field to
apply_police_params(). Due to this when police rate is higher
than 4Gbps, 32-bit calculation ignores the carry. This results
in incorrect rate configurationn the device.
Fix it by performing 64-bit calculation.
Fixes: fcb64c0f5640 ("net/mlx5: E-Switch, add ingress rate support")
Signed-off-by: Parav Pandit <[email protected]>
Reviewed-by: Eli Cohen <[email protected]>
Signed-off-by: Saeed Mahameed <[email protected]>
Signed-off-by: Sasha Levin <[email protected]>
---
drivers/net/ethernet/mellanox/mlx5/core/en_tc.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/drivers/net/ethernet/mellanox/mlx5/core/en_tc.c
b/drivers/net/ethernet/mellanox/mlx5/core/en_tc.c
index dd0bfbacad474..717fbaa6ce736 100644
--- a/drivers/net/ethernet/mellanox/mlx5/core/en_tc.c
+++ b/drivers/net/ethernet/mellanox/mlx5/core/en_tc.c
@@ -5040,7 +5040,7 @@ static int apply_police_params(struct mlx5e_priv *priv,
u64 rate,
*/
if (rate) {
rate = (rate * BITS_PER_BYTE) + 500000;
- rate_mbps = max_t(u32, do_div(rate, 1000000), 1);
+ rate_mbps = max_t(u64, do_div(rate, 1000000), 1);
}
err = mlx5_esw_modify_vport_rate(esw, vport_num, rate_mbps);
--
2.27.0