From: Richard Gong <richard.g...@intel.com>

Clean up COMMAND_RECONFIG_FLAG_PARTIAL flag by resetting it to 0, which
aligns with the firmware settings.

Signed-off-by: Richard Gong <richard.g...@intel.com>
---
 include/linux/firmware/intel/stratix10-svc-client.h | 6 +++---
 1 file changed, 3 insertions(+), 3 deletions(-)

diff --git a/include/linux/firmware/intel/stratix10-svc-client.h 
b/include/linux/firmware/intel/stratix10-svc-client.h
index ebc2956..1ffb982 100644
--- a/include/linux/firmware/intel/stratix10-svc-client.h
+++ b/include/linux/firmware/intel/stratix10-svc-client.h
@@ -51,12 +51,12 @@
 #define SVC_STATUS_NO_SUPPORT          6
 
 /*
- * Flag bit for COMMAND_RECONFIG
+ * Flag for COMMAND_RECONFIG, in bit number
  *
  * COMMAND_RECONFIG_FLAG_PARTIAL:
- * Set to FPGA configuration type (full or partial).
+ * Set for partial configuration.
  */
-#define COMMAND_RECONFIG_FLAG_PARTIAL  1
+#define COMMAND_RECONFIG_FLAG_PARTIAL  0
 
 /*
  * Timeout settings for service clients:
-- 
2.7.4