From: Oleksij Rempel <o.rem...@pengutronix.de>

[ Upstream commit 820830ec918f6c3dcd77a54a1c6198ab57407916 ]

In some rare cases the 32 bit Rt value will overflow if z2 and x is max,
z1 is minimal value and x_plate_ohms is relatively high (for example 800
ohm). This would happen on some screen age with low pressure.

There are two possible fixes:
- make Rt 64bit
- reorder calculation to avoid overflow

The second variant seems to be preferable, since 64 bit calculation on
32 bit system is a bit more expensive.

Fixes: ffa458c1bd9b6f653008d450f337602f3d52a646 ("spi: ads7846 driver")
Co-developed-by: David Jander <da...@protonic.nl>
Signed-off-by: David Jander <da...@protonic.nl>
Signed-off-by: Oleksij Rempel <o.rem...@pengutronix.de>
Link: https://lore.kernel.org/r/20201113112240.1360-1-o.rem...@pengutronix.de
Signed-off-by: Dmitry Torokhov <dmitry.torok...@gmail.com>
Signed-off-by: Sasha Levin <sas...@kernel.org>
---
 drivers/input/touchscreen/ads7846.c | 5 +++--
 1 file changed, 3 insertions(+), 2 deletions(-)

diff --git a/drivers/input/touchscreen/ads7846.c 
b/drivers/input/touchscreen/ads7846.c
index 69992d5e53118..78ed285c27ae3 100644
--- a/drivers/input/touchscreen/ads7846.c
+++ b/drivers/input/touchscreen/ads7846.c
@@ -802,10 +802,11 @@ static void ads7846_report_state(struct ads7846 *ts)
                /* compute touch pressure resistance using equation #2 */
                Rt = z2;
                Rt -= z1;
-               Rt *= x;
                Rt *= ts->x_plate_ohms;
+               Rt = DIV_ROUND_CLOSEST(Rt, 16);
+               Rt *= x;
                Rt /= z1;
-               Rt = (Rt + 2047) >> 12;
+               Rt = DIV_ROUND_CLOSEST(Rt, 256);
        } else {
                Rt = 0;
        }
-- 
2.27.0