On Mon, 2020-10-26 at 17:12 +0000, Bernd Petrovitsch wrote: > Hi all! > > On 25/10/2020 16:11, Michael J. Baars wrote: > [...] > > I've been writing a simple client and server for cluster computing this > > weekend. At first everything appeared to work just fine, but soon enough I > > found > > some > > inexplicable bind errors. I've tried to make sure that the client closes > > it's sockets before the server closes it's sockets, to prevent linger, but > > trying > > did > > Which were exactly? > English/original text pls ... > > And The close() (and shutdown() syscalls, respectively) don't avoid > the FIN_WAIT2 timeout on a closed socket. > Just set the SO_REUSEADDR socket option on the listening socket. > > > not help. Now I think I found the problem. > > Then solve it. > > > Please do have a look at the code. It looks like the SIGHUP is sent to the > > server not on close or exit, but on the connect instead. > > Too lazy to save and uncompress the file ... > > MfG, > Bernd
And I think this was sort of part of the question: We have on sock[0] serverside 1 SIGHUP on the connect We have on sock[1] serverside about 7 SIGHUPs on the close Why not sent these 6 or 7 SIGHUPs on sock[0], such that the SIGHUP handler has to be installed only once? Regards, Mischa.