Hi,

On Wed, Jul 15, 2020 at 10:55:12PM +0800, Crag Wang wrote:
> This is a long life mode set in the factory for extended warranty
> battery, the power charging rate is customized so that battery at
> work last longer.
> 
> Presently switching to a different battery charging mode is through
> EC PID 0x0710 to configure the battery firmware, this operation will
> be blocked by EC with failure code 0x01 when PLL mode is already
> in use.
> 
> Signed-off-by: Crag Wang <crag.w...@dell.com>
> ---
>  Documentation/ABI/testing/sysfs-class-power-wilco | 3 +++
>  drivers/power/supply/power_supply_sysfs.c         | 1 +
>  drivers/power/supply/wilco-charger.c              | 5 +++++
>  include/linux/power_supply.h                      | 1 +
>  4 files changed, 10 insertions(+)
> 
> diff --git a/Documentation/ABI/testing/sysfs-class-power-wilco 
> b/Documentation/ABI/testing/sysfs-class-power-wilco
> index da1d6ffe5e3c..1c91b17b6fd4 100644
> --- a/Documentation/ABI/testing/sysfs-class-power-wilco
> +++ b/Documentation/ABI/testing/sysfs-class-power-wilco
> @@ -14,6 +14,9 @@ Description:
>                       Charging begins when level drops below
>                       charge_control_start_threshold, and ceases when
>                       level is above charge_control_end_threshold.
> +             Permanent Long Life: Last longer battery life, this mode
> +                     is programmed once in the factory. Switching to a
> +                     different mode is unavailable.

The documentation lacks one important aspect: What happens
if I have a device where the factory did not program "Long Life"?
I.e. what happens when

# cat /sys/class/power_supply/wilco-charger/charge_type
Standard
# echo "Long Life" > /sys/class/power_supply/wilco-charger/charge_type

Will the controller switch into permanent long life battery mode
without any exit strategy?

>  What:                
> /sys/class/power_supply/wilco-charger/charge_control_start_threshold
>  Date:                April 2019
> diff --git a/drivers/power/supply/power_supply_sysfs.c 
> b/drivers/power/supply/power_supply_sysfs.c
> index bc79560229b5..af3884015ad8 100644
> --- a/drivers/power/supply/power_supply_sysfs.c
> +++ b/drivers/power/supply/power_supply_sysfs.c
> @@ -87,6 +87,7 @@ static const char * const POWER_SUPPLY_CHARGE_TYPE_TEXT[] = 
> {
>       [POWER_SUPPLY_CHARGE_TYPE_STANDARD]     = "Standard",
>       [POWER_SUPPLY_CHARGE_TYPE_ADAPTIVE]     = "Adaptive",
>       [POWER_SUPPLY_CHARGE_TYPE_CUSTOM]       = "Custom",
> +     [POWER_SUPPLY_CHARGE_TYPE_LONGLIFE]     = "Permanent Long Life",

The "Permanent" part is specific to the Wilco EC, so I think it's
better to avoid it in the generic API. I think it's better to use
just "Long Life" (and keep the wilco specific sysfs Documentation,
that Long Life configuration is permanent).

-- Sebastian

>  };
>  
>  static const char * const POWER_SUPPLY_HEALTH_TEXT[] = {
> diff --git a/drivers/power/supply/wilco-charger.c 
> b/drivers/power/supply/wilco-charger.c
> index b3c6d7cdd731..713c3018652f 100644
> --- a/drivers/power/supply/wilco-charger.c
> +++ b/drivers/power/supply/wilco-charger.c
> @@ -27,6 +27,7 @@ enum charge_mode {
>       CHARGE_MODE_AC = 3,     /* Mostly AC use, used for Trickle */
>       CHARGE_MODE_AUTO = 4,   /* Used for Adaptive */
>       CHARGE_MODE_CUSTOM = 5, /* Used for Custom */
> +     CHARGE_MODE_LONGLIFE = 6, /* Used for Permanent Long Life */
>  };
>  
>  #define CHARGE_LOWER_LIMIT_MIN       50
> @@ -48,6 +49,8 @@ static int psp_val_to_charge_mode(int psp_val)
>               return CHARGE_MODE_AUTO;
>       case POWER_SUPPLY_CHARGE_TYPE_CUSTOM:
>               return CHARGE_MODE_CUSTOM;
> +     case POWER_SUPPLY_CHARGE_TYPE_LONGLIFE:
> +             return CHARGE_MODE_LONGLIFE;
>       default:
>               return -EINVAL;
>       }
> @@ -67,6 +70,8 @@ static int charge_mode_to_psp_val(enum charge_mode mode)
>               return POWER_SUPPLY_CHARGE_TYPE_ADAPTIVE;
>       case CHARGE_MODE_CUSTOM:
>               return POWER_SUPPLY_CHARGE_TYPE_CUSTOM;
> +     case CHARGE_MODE_LONGLIFE:
> +             return POWER_SUPPLY_CHARGE_TYPE_LONGLIFE;
>       default:
>               return -EINVAL;
>       }
> diff --git a/include/linux/power_supply.h b/include/linux/power_supply.h
> index ac1345a48ad0..528a3eaa2320 100644
> --- a/include/linux/power_supply.h
> +++ b/include/linux/power_supply.h
> @@ -48,6 +48,7 @@ enum {
>       POWER_SUPPLY_CHARGE_TYPE_STANDARD,      /* normal speed */
>       POWER_SUPPLY_CHARGE_TYPE_ADAPTIVE,      /* dynamically adjusted speed */
>       POWER_SUPPLY_CHARGE_TYPE_CUSTOM,        /* use CHARGE_CONTROL_* props */
> +     POWER_SUPPLY_CHARGE_TYPE_LONGLIFE,      /* slow speed, longer life */
>  };
>  
>  enum {
> -- 
> 2.17.1
> 
> ---
> The original author, Nick no longer being around and that's why he's not on 
> CC.