Extend thermal trip point type property to include "cold" trip type
indicating point in the temperature domain below which a warming action
must be intiated.

Signed-off-by: Thara Gopinath <thara.gopin...@linaro.org>
---
 Documentation/devicetree/bindings/thermal/thermal.txt | 1 +
 1 file changed, 1 insertion(+)

diff --git a/Documentation/devicetree/bindings/thermal/thermal.txt 
b/Documentation/devicetree/bindings/thermal/thermal.txt
index f78bec19ca35..1689d9ba1471 100644
--- a/Documentation/devicetree/bindings/thermal/thermal.txt
+++ b/Documentation/devicetree/bindings/thermal/thermal.txt
@@ -87,6 +87,7 @@ Required properties:
        "active":       A trip point to enable active cooling
        "passive":      A trip point to enable passive cooling
        "hot":          A trip point to notify emergency
+       "cold":         A trip point to enable warming
        "critical":     Hardware not reliable.
   Type: string
 
-- 
2.25.1