On Tue, May 26, 2020 at 10:35:04AM -0700, Guru Das Srinagesh wrote: > Since the PWM framework is switching struct pwm_args.period's datatype > to u64, prepare for this transition by using DIV64_U64_ROUND_CLOSEST to > handle a 64-bit divisor. > > Cc: Daniel Thompson <[email protected]> > Signed-off-by: Guru Das Srinagesh <[email protected]> > --- > drivers/pwm/pwm-clps711x.c | 2 +- > 1 file changed, 1 insertion(+), 1 deletion(-) > > diff --git a/drivers/pwm/pwm-clps711x.c b/drivers/pwm/pwm-clps711x.c > index 924d39a..ba9500a 100644 > --- a/drivers/pwm/pwm-clps711x.c > +++ b/drivers/pwm/pwm-clps711x.c > @@ -43,7 +43,7 @@ static void clps711x_pwm_update_val(struct clps711x_chip > *priv, u32 n, u32 v) > static unsigned int clps711x_get_duty(struct pwm_device *pwm, unsigned int v) > { > /* Duty cycle 0..15 max */ > - return DIV_ROUND_CLOSEST(v * 0xf, pwm->args.period); > + return DIV64_U64_ROUND_CLOSEST(v * 0xf, pwm->args.period); > } > > static int clps711x_pwm_request(struct pwm_chip *chip, struct pwm_device > *pwm) > --
Hi Daniel, Could you please review this patch when you get a chance to? Thank you. Guru Das.