On Tue, May 26, 2020 at 10:35:04AM -0700, Guru Das Srinagesh wrote:
> Since the PWM framework is switching struct pwm_args.period's datatype
> to u64, prepare for this transition by using DIV64_U64_ROUND_CLOSEST to
> handle a 64-bit divisor.
> 
> Cc: Daniel Thompson <[email protected]>
> Signed-off-by: Guru Das Srinagesh <[email protected]>
> ---
>  drivers/pwm/pwm-clps711x.c | 2 +-
>  1 file changed, 1 insertion(+), 1 deletion(-)
> 
> diff --git a/drivers/pwm/pwm-clps711x.c b/drivers/pwm/pwm-clps711x.c
> index 924d39a..ba9500a 100644
> --- a/drivers/pwm/pwm-clps711x.c
> +++ b/drivers/pwm/pwm-clps711x.c
> @@ -43,7 +43,7 @@ static void clps711x_pwm_update_val(struct clps711x_chip 
> *priv, u32 n, u32 v)
>  static unsigned int clps711x_get_duty(struct pwm_device *pwm, unsigned int v)
>  {
>       /* Duty cycle 0..15 max */
> -     return DIV_ROUND_CLOSEST(v * 0xf, pwm->args.period);
> +     return DIV64_U64_ROUND_CLOSEST(v * 0xf, pwm->args.period);
>  }
>  
>  static int clps711x_pwm_request(struct pwm_chip *chip, struct pwm_device 
> *pwm)
> -- 

Hi Daniel,

Could you please review this patch when you get a chance to?

Thank you.

Guru Das.

Reply via email to