Hi,

Usually, when developing the clock controller driver,
define the same sequence between the definition sequence in dt-bibing
and clock driver. As I replied, if you squash patches, it is easy.

For example,
This series add clock id as following.
                                                                             
 569         MUX(CLK_MOUT_ACLK400_ISP, "mout_aclk400_isp", mout_group1_p,       
     
 570                         SRC_TOP0, 0, 2),                                   
     
 571         MUX(CLK_MOUT_ACLK400_MSCL, "mout_aclk400_mscl", mout_group1_p,     
     
 572                         SRC_TOP0, 4, 2),                                   
     
 573         MUX(CLK_MOUT_ACLK400_WCORE, "mout_aclk400_wcore", mout_group1_p,   
     
 574                         SRC_TOP0, 16, 2),                                  
     
 575         MUX(CLK_MOUT_ACLK100_NOC, "mout_aclk100_noc", mout_group1_p,       
     
 576                         SRC_TOP0, 20, 2),          

In case of this code, you can define the IDs as following sequentially:

#define CLK_MOUT_ACLK400_ISP ...
#define CLK_MOUT_ACLK400_MSCL ... 
#define CLK_MOUT_ACLK400_WCORE ...
#define CLK_MOUT_ACLK100_NOC ...


But, this series define the ID as following:
        #define CLK_MOUT_ACLK400_WCORE          662                             
        
#define CLK_MOUT_SCLK_DPLL      663                                             
        #define CLK_MOUT_ACLK100_NOC    664                                     
        
#define CLK_MOUT_ACLK200_FSYS2  665                                             
#define CLK_MOUT_PCLK200_FSYS   666                                             
#define CLK_MOUT_ACLK200_FSYS   667                                             
        #define CLK_MOUT_ACLK400_ISP    668                                     
        
        #define CLK_MOUT_ACLK400_MSCL   669                                     
        
#define CLK_MOUT_SCLK_MPLL      700                                             
#define CLK_MOUT_ACLK266        701                                             
#define CLK_MOUT_UART0          702                                             
#define CLK_MOUT_UART1          703                                             
#define CLK_MOUT_UART2          704                                             
#define CLK_MOUT_UART3          7

On 19. 7. 15. 오후 9:43, Lukasz Luba wrote:
> There is a need of new IDs which will be used for modeling proper hierarchy
> in the Exynos54xx SoCs. Previous implementation rely on bootloader
> settings, which are not configuring properly some clocks.
> These IDs provide interface to set proper parents.
> 
> Signed-off-by: Lukasz Luba <l.l...@partner.samsung.com>
> ---
>  include/dt-bindings/clock/exynos5420.h | 27 +++++++++++++++++++++++++-
>  1 file changed, 26 insertions(+), 1 deletion(-)
> 
> diff --git a/include/dt-bindings/clock/exynos5420.h 
> b/include/dt-bindings/clock/exynos5420.h
> index 02d5ac469a3d..c37a28eeaf7e 100644
> --- a/include/dt-bindings/clock/exynos5420.h
> +++ b/include/dt-bindings/clock/exynos5420.h
> @@ -230,6 +230,30 @@
>  #define CLK_MOUT_USER_MAU_EPLL       659
>  #define CLK_MOUT_SCLK_SPLL   660
>  #define CLK_MOUT_MX_MSPLL_CCORE_PHY  661
> +#define CLK_MOUT_ACLK400_WCORE               662
> +#define CLK_MOUT_SCLK_DPLL   663
> +#define CLK_MOUT_ACLK100_NOC 664
> +#define CLK_MOUT_ACLK200_FSYS2       665
> +#define CLK_MOUT_PCLK200_FSYS        666
> +#define CLK_MOUT_ACLK200_FSYS        667
> +#define CLK_MOUT_ACLK400_ISP 668
> +#define CLK_MOUT_ACLK400_MSCL        669
> +#define CLK_MOUT_SCLK_MPLL   700
> +#define CLK_MOUT_ACLK266     701
> +#define CLK_MOUT_UART0               702
> +#define CLK_MOUT_UART1               703
> +#define CLK_MOUT_UART2               704
> +#define CLK_MOUT_UART3               705
> +#define CLK_MOUT_SCLK_CPLL   706
> +#define CLK_MOUT_PWM         707
> +#define CLK_MOUT_ACLK266_G2D         708
> +#define CLK_MOUT_SW_ACLK400_WCORE    709
> +#define CLK_MOUT_SW_ACLK400_MSCL     710
> +#define CLK_MOUT_SW_ACLK400_ISP              711
> +#define CLK_MOUT_SW_ACLK266_ISP              712
> +#define CLK_MOUT_USER_ACLK266_ISP    713
> +#define CLK_MOUT_ACLK266_ISP 714
> +#define CLK_MOUT_MMC0                715
>  
>  /* divider clocks */
>  #define CLK_DOUT_PIXEL               768
> @@ -264,8 +288,9 @@
>  #define CLK_FF_DOUT_SPLL2    797
>  #define CLK_DOUT_PCLK_DREX0  798
>  #define CLK_DOUT_PCLK_DREX1  799
> +#define CLK_DOUT_ACLK266_ISP 800
>  
>  /* must be greater than maximal clock id */
> -#define CLK_NR_CLKS          800
> +#define CLK_NR_CLKS          801
>  
>  #endif /* _DT_BINDINGS_CLOCK_EXYNOS_5420_H */
> 


-- 