Hi Suzuki, Mathieu, On Tue, May 28, 2019 at 01:19:24PM +0800, Leo Yan wrote:
[...] > After I applied this patch set, I found all device names under > '/sys/bus/event_source/devices/cs_etm/sinks/' have been changed as > below on my DB410c board: > # ls /sys/bus/event_source/devices/cs_etm/sinks/ > tmc_etf0 tmc_etr0 tpiu0 > > This leads to below command failure when open PMU device: > # perf record -e cs_etm/@826000.etr/ --per-thread uname > failed to set sink "826000.etr" on event cs_etm/@826000.etr/ with 2 (No such > file or directory) > > I must use below command so that perf can match string with the > device name under '/sys/bus/event_source/devices/cs_etm/sinks/': > # perf record -e cs_etm/@tmc_etr0/ --per-thread uname > > Seems to me, this is an unexpected change and when I worked on the > patch set v2, IIRC that version still can use '826000.etr' to open PMU > device. > > Please help confirm for this. Thanks! Finally, this is narrowed down to the patch 09/30 'coresight: Use coresight device names for sinks in PMU attribute', so this is delibrately to change to use new name format for perf command; if so, maybe also update the documentation to reflect this change? Thanks, Leo Yan