4.9-stable review patch.  If anyone has any objections, please let me know.

------------------

From: Matt Ranostay <matt.ranos...@konsulko.com>

commit 0808831dc62e90023ad14ff8da4804c7846e904b upstream.

IIO_TEMP scale value for temperature was incorrect and not in millicelsius
as required by the ABI documentation.

Signed-off-by: Matt Ranostay <matt.ranos...@konsulko.com>
Fixes: 27dec00ecf2d (iio: chemical: add Atlas pH-SM sensor support)
Cc: <sta...@vger.kernel.org>
Signed-off-by: Jonathan Cameron <jonathan.came...@huawei.com>
Signed-off-by: Greg Kroah-Hartman <gre...@linuxfoundation.org>

---
 drivers/iio/chemical/atlas-ph-sensor.c |    7 +++----
 1 file changed, 3 insertions(+), 4 deletions(-)

--- a/drivers/iio/chemical/atlas-ph-sensor.c
+++ b/drivers/iio/chemical/atlas-ph-sensor.c
@@ -453,9 +453,8 @@ static int atlas_read_raw(struct iio_dev
        case IIO_CHAN_INFO_SCALE:
                switch (chan->type) {
                case IIO_TEMP:
-                       *val = 1; /* 0.01 */
-                       *val2 = 100;
-                       break;
+                       *val = 10;
+                       return IIO_VAL_INT;
                case IIO_PH:
                        *val = 1; /* 0.001 */
                        *val2 = 1000;
@@ -486,7 +485,7 @@ static int atlas_write_raw(struct iio_de
                           int val, int val2, long mask)
 {
        struct atlas_data *data = iio_priv(indio_dev);
-       __be32 reg = cpu_to_be32(val);
+       __be32 reg = cpu_to_be32(val / 10);
 
        if (val2 != 0 || val < 0 || val > 20000)
                return -EINVAL;