On Wed, 29 Aug 2018, Matti Vaittinen wrote:

> There is a HW quirk in BD71837. The shutdown sequence timings for
> bucks/LDOs which are enabled via register interface are changed.
> At PMIC poweroff the voltage for BUCK6/7 is cut immediately at the
> beginning of shut-down sequence. This causes LDO5/6 voltage
> monitoring to detect under voltage and force PMIC to emergency
> state instead of poweroff. Disable voltage monitoring for LDO5 and
> LDO6 at probe to avoid this.
> 
> Signed-off-by: Matti Vaittinen <matti.vaitti...@fi.rohmeurope.com>
> ---
>  drivers/regulator/bd71837-regulator.c | 19 +++++++++++++++++++

>  include/linux/mfd/rohm-bd718x7.h      | 33 ++++++++++++++++++++++++++++++---

For my own reference:
  Acked-for-MFD-by: Lee Jones <lee.jo...@linaro.org>

-- 
Lee Jones [李琼斯]
Linaro Services Technical Lead
Linaro.org │ Open source software for ARM SoCs
Follow Linaro: Facebook | Twitter | Blog