On Thu, Jul 12, 2018 at 10:37:37AM +0530, Keerthy wrote:
> Cut down the shutdown time from 2 seconds to 1 sec. In case of roll
> over try again.
> 
> Signed-off-by: Keerthy <j-keer...@ti.com>

> @@ -435,17 +435,23 @@ static void omap_rtc_power_off(void)

> +     /* set alarm one second from now */
>       omap_rtc_read_time_raw(rtc, &tm);
> +     seconds = tm.tm_sec;
>       bcd2tm(&tm);
>       rtc_tm_to_time(&tm, &now);
> -     rtc_time_to_tm(now + 2, &tm);
> +     rtc_time_to_tm(now + 1, &tm);

One more thing, the comment before final mdelay as well as that delay
itself also needs to be updated to reflect this change.

Thanks,
Johan

Reply via email to