Hi,

On Wednesday 30 May 2018 08:27 PM, Tony Lindgren wrote:
> * Faiz Abbas <faiz_ab...@ti.com> [180530 14:12]:
>> The dra76x MCAN generic interconnect module has a its own
>> format for the bits in the control registers.
...
>>  static int sysc_init_pdata(struct sysc *ddata)
>>  {
>>      struct ti_sysc_platform_data *pdata = dev_get_platdata(ddata->dev);
>> @@ -1441,6 +1457,7 @@ static const struct of_device_id sysc_match[] = {
>>      { .compatible = "ti,sysc-mcasp", .data = &sysc_omap4_mcasp, },
>>      { .compatible = "ti,sysc-usb-host-fs",
>>        .data = &sysc_omap4_usb_host_fs, },
>> +    { .compatible = "ti,sysc-dra7-mcan", .data = &sysc_dra7_mcan, },
>>      {  },
>>  };
> 
> Looks good to me. And presumably you checked that no other dra7 modules
> use sysconfig register bit layout like this?
> 

As far as I could see, Yes.

Thanks,
Faiz

Reply via email to