Reset EP when disable it to reset data toggle for U2 EP, and
SeqN, flow control status etc for U3 EP, this can avoid
issue of uncontinuous SeqN

Signed-off-by: Chunfeng Yun <chunfeng....@mediatek.com>
---
v2:
    add this patch
---
 drivers/usb/mtu3/mtu3_core.c | 4 ++++
 1 file changed, 4 insertions(+)

diff --git a/drivers/usb/mtu3/mtu3_core.c b/drivers/usb/mtu3/mtu3_core.c
index 65ff53a..0bc2b39 100644
--- a/drivers/usb/mtu3/mtu3_core.c
+++ b/drivers/usb/mtu3/mtu3_core.c
@@ -400,6 +400,10 @@ void mtu3_deconfig_ep(struct mtu3 *mtu, struct mtu3_ep 
*mep)
                mtu3_setbits(mbase, U3D_QIECR0, QMU_RX_DONE_INT(epnum));
        }
 
+       /* reset: u2 - data toggle, u3 - SeqN, flow control status etc */
+       mtu3_setbits(mbase, U3D_EP_RST, EP_RST(mep->is_in, epnum));
+       mtu3_clrbits(mbase, U3D_EP_RST, EP_RST(mep->is_in, epnum));
+
        ep_fifo_free(mep);
 
        dev_dbg(mtu->dev, "%s: %s\n", __func__, mep->name);
-- 
1.9.1