On Fri, Nov 10, 2017 at 01:49:45AM -0800, Wanpeng Li wrote:
> +static DEFINE_PER_CPU(cpumask_var_t, __pv_tlb_mask);
> +
> +static void kvm_flush_tlb_others(const struct cpumask *cpumask,
> +                     const struct flush_tlb_info *info)
> +{
> +     u8 state;
> +     int cpu;
> +     struct kvm_steal_time *src;
> +     struct cpumask *flushmask = this_cpu_cpumask_var_ptr(__pv_tlb_mask);
> +
> +     if (unlikely(!flushmask))
> +             return;
> +
> +     cpumask_copy(flushmask, cpumask);
> +     /*
> +      * We have to call flush only on online vCPUs. And
> +      * queue flush_on_enter for pre-empted vCPUs
> +      */
> +     for_each_cpu(cpu, cpumask) {
> +             src = &per_cpu(steal_time, cpu);
> +             state = src->preempted;

I think that wants to be: state = READ_ONCE(src->preempted);

Because without that its possible for state to get re-loaded between the
check here:

> +             if ((state & KVM_VCPU_PREEMPTED)) {

and its use here.

> +                     if (cmpxchg(&src->preempted, state, state |
> +                             KVM_VCPU_SHOULD_FLUSH) == state)

You can actually write that like:

                        if (try_cmpxchg(&src->preempted, state,
                                        state | KVM_VCPU_SHOULD_FLUSH))

Which should generate ever so slightly better code (it uses the cmpxchg
ZF instead of doing a superfluous compare).

> +                             __cpumask_clear_cpu(cpu, flushmask);
> +             }
> +     }
> +
> +     native_flush_tlb_others(flushmask, info);
> +}