On Wed, 2007-03-28 at 10:43 -0700, Sumant Patro wrote:
> eh_timed_out call back (megasas_reset_timer) is used to throttle io to the 
> adapter 
> when it is called the first time for a scmd.
> The MEGASAS_FW_BUSY flag is set and can_queue reduced to 16. The can_queue is 
> restored 
> from completion routine in following two conditions : 5 seconds has elapsed 
> and the # of
> outstanding cmds in FW is < 17.
> 
> Signed-off-by: Sumant Patro <[EMAIL PROTECTED]>
> ---
>  drivers/scsi/megaraid/megaraid_sas.c |   65 +++++++++++++++++++++++--
>  drivers/scsi/megaraid/megaraid_sas.h |   13 +++--
>  2 files changed, 70 insertions(+), 8 deletions(-)
> 
> This patch requires the patch submitted by James with subject line : 
> 
> [PATCH] expose eh_timed_out to the host template
> 
> diff -uprN linux-2.6.orig/drivers/scsi/megaraid/megaraid_sas.c 
> linux-2.6.new/drivers/scsi/megaraid/megaraid_sas.c
> --- linux-2.6.orig/drivers/scsi/megaraid/megaraid_sas.c       2007-03-28 
> 08:41:49.000000000 -0700
> +++ linux-2.6.new/drivers/scsi/megaraid/megaraid_sas.c        2007-03-28 
> 08:36:38.000000000 -0700
> @@ -10,7 +10,7 @@
>   *      2 of the License, or (at your option) any later version.
>   *
>   * FILE              : megaraid_sas.c
> - * Version   : v00.00.03.10-rc1
> + * Version   : v00.00.03.10-rc3
>   *
>   * Authors:
>   *   (email-id : [EMAIL PROTECTED])
> @@ -886,6 +886,7 @@ megasas_queue_command(struct scsi_cmnd *
>               goto out_return_cmd;
>  
>       cmd->scmd = scmd;
> +     scmd->SCp.ptr = (char *)cmd;
>  
>       /*
>        * Issue the command to the FW
> @@ -981,8 +982,8 @@ static int megasas_generic_reset(struct 
>  
>       instance = (struct megasas_instance *)scmd->device->host->hostdata;
>  
> -     scmd_printk(KERN_NOTICE, scmd, "megasas: RESET -%ld cmd=%x\n",
> -            scmd->serial_number, scmd->cmnd[0]);
> +     scmd_printk(KERN_NOTICE, scmd, "megasas: RESET -%ld cmd=%x 
> retries=%x\n",
> +              scmd->serial_number, scmd->cmnd[0], scmd->retries);
>  
>       if (instance->hw_crit_error) {
>               printk(KERN_ERR "megasas: cannot recover from previous reset "
> @@ -1000,6 +1001,40 @@ static int megasas_generic_reset(struct 
>  }
>  
>  /**
> + * megasas_reset_timer - quiesce the adapter if required
> + * @scmd:            scsi cmnd
> + *
> + * Sets the FW busy flag and reduces the host->can_queue if the
> + * cmd has not been completed within the timeout period.
> + */
> +static enum
> +scsi_eh_timer_return megasas_reset_timer(struct scsi_cmnd *scmd)
> +{
> +     struct megasas_cmd *cmd = (struct megasas_cmd *)scmd->SCp.ptr;
> +     struct megasas_instance *instance;
> +     unsigned long flags;
> +
> +     if (cmd) {

I don't believe we can ever get a command timeout with no command, can
we?

> +             if (time_after(jiffies, scmd->jiffies_at_alloc + 170 * HZ))
> +                     return EH_NOT_HANDLED;

This 170s is a bit arbitrary ... surely you want it to be related to a
multiple of scmd->timeout_per_command?

> +             instance = cmd->instance;
> +             if (!(instance->flag & MEGASAS_FW_BUSY)) {
> +                     /* FW is busy, throttle IO */
> +                     spin_lock_irqsave(&instance->throttle_io_lock, flags);
> +
> +                     instance->host->can_queue = 16;

can_queue is protected by the host lock ... I think you need to dump the
throttle_io_lock and simply use the host lock for all of this.

> +                     instance->last_time = jiffies;
> +                     instance->flag |= MEGASAS_FW_BUSY;
> +
> +                     spin_unlock_irqrestore(&instance->throttle_io_lock, 
> flags);
> +             }
> +             return EH_RESET_TIMER;
> +     }
> +     return EH_HANDLED;
> +}
> +
> +/**
>   * megasas_reset_device -    Device reset handler entry point
>   */
>  static int megasas_reset_device(struct scsi_cmnd *scmd)
> @@ -1112,6 +1147,7 @@ static struct scsi_host_template megasas
>       .eh_device_reset_handler = megasas_reset_device,
>       .eh_bus_reset_handler = megasas_reset_bus_host,
>       .eh_host_reset_handler = megasas_reset_bus_host,
> +     .eh_timed_out = megasas_reset_timer,
>       .bios_param = megasas_bios_param,
>       .use_clustering = ENABLE_CLUSTERING,
>  };
> @@ -1215,9 +1251,8 @@ megasas_complete_cmd(struct megasas_inst
>       int exception = 0;
>       struct megasas_header *hdr = &cmd->frame->hdr;
>  
> -     if (cmd->scmd) {
> +     if (cmd->scmd)
>               cmd->scmd->SCp.ptr = (char *)0;

That's NULL, ordinarily ...

> -     }
>  
>       switch (hdr->cmd) {
>  
> @@ -1806,6 +1841,7 @@ static void megasas_complete_cmd_dpc(uns
>       u32 context;
>       struct megasas_cmd *cmd;
>       struct megasas_instance *instance = (struct megasas_instance 
> *)instance_addr;
> +     unsigned long flags;
>  
>       /* If we have already declared adapter dead, donot complete cmds */
>       if (instance->hw_crit_error)
> @@ -1828,6 +1864,22 @@ static void megasas_complete_cmd_dpc(uns
>       }
>  
>       *instance->consumer = producer;
> +
> +     /*
> +      * Check if we can restore can_queue
> +      */
> +     if (instance->flag & MEGASAS_FW_BUSY
> +             && time_after(jiffies, instance->last_time + 5 * HZ)
> +             && atomic_read(&instance->fw_outstanding) < 17) {
> +
> +             spin_lock_irqsave(&instance->throttle_io_lock, flags);
> +
> +             instance->flag &= ~MEGASAS_FW_BUSY;
> +             instance->host->can_queue =
> +                             instance->max_fw_cmds - MEGASAS_INT_CMDS;
> +
> +             spin_unlock_irqrestore(&instance->throttle_io_lock, flags);
> +     }
>  }
>  
>  /**
> @@ -2384,6 +2436,7 @@ megasas_probe_one(struct pci_dev *pdev, 
>       init_waitqueue_head(&instance->int_cmd_wait_q);
>       init_waitqueue_head(&instance->abort_cmd_wait_q);
>  
> +     spin_lock_init(&instance->throttle_io_lock);
>       spin_lock_init(&instance->cmd_pool_lock);
>  
>       sema_init(&instance->aen_mutex, 1);
> @@ -2398,6 +2451,8 @@ megasas_probe_one(struct pci_dev *pdev, 
>       instance->init_id = MEGASAS_DEFAULT_INIT_ID;
>  
>       megasas_dbg_lvl = 0;
> +     instance->flag = 0;
> +     instance->last_time = 0;
>  
>       /*
>        * Initialize MFI Firmware
> diff -uprN linux-2.6.orig/drivers/scsi/megaraid/megaraid_sas.h 
> linux-2.6.new/drivers/scsi/megaraid/megaraid_sas.h
> --- linux-2.6.orig/drivers/scsi/megaraid/megaraid_sas.h       2007-03-28 
> 08:41:49.000000000 -0700
> +++ linux-2.6.new/drivers/scsi/megaraid/megaraid_sas.h        2007-03-28 
> 08:36:39.000000000 -0700
> @@ -18,9 +18,9 @@
>  /*
>   * MegaRAID SAS Driver meta data
>   */
> -#define MEGASAS_VERSION                              "00.00.03.10-rc1"
> -#define MEGASAS_RELDATE                              "Feb 14, 2007"
> -#define MEGASAS_EXT_VERSION                  "Wed Feb 14 10:14:25 PST 2007"
> +#define MEGASAS_VERSION                              "00.00.03.10-rc3"
> +#define MEGASAS_RELDATE                              "Mar 28, 2007"
> +#define MEGASAS_EXT_VERSION                  "Wed Mar 28 10:25:52 PST 2007"
>  
>  /*
>   * Device IDs
> @@ -539,6 +539,8 @@ struct megasas_ctrl_info {
>  
>  #define MEGASAS_DBG_LVL                              1
>  
> +#define MEGASAS_FW_BUSY                              1
> +
>  /*
>   * When SCSI mid-layer calls driver's reset routine, driver waits for
>   * MEGASAS_RESET_WAIT_TIME seconds for all outstanding IO to complete. Note
> @@ -1104,6 +1106,11 @@ struct megasas_instance {
>  
>       struct megasas_instance_template *instancet;
>       struct tasklet_struct isr_tasklet;
> +
> +     u8 flag;
> +     u8 rsvd[3];

What's this rsvd?  I don't see it used anywhere in the code ...

> +     unsigned long last_time;
> +     spinlock_t throttle_io_lock;
>  };
>  
>  #define MEGASAS_IS_LOGICAL(scp)                                              
> \

James


-
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to [EMAIL PROTECTED]
More majordomo info at  http://vger.kernel.org/majordomo-info.html
Please read the FAQ at  http://www.tux.org/lkml/

Reply via email to