The binding says that the compatible string must be "ti,am33xx-elm" but the code checks only for, and all functioning users set, this as "ti,am3352-elm" so correct the binding.
Cc: David Woodhouse <dw...@infradead.org> Cc: Brian Norris <computersforpe...@gmail.com> Cc: Boris Brezillon <boris.brezil...@free-electrons.com> Cc: Marek Vasut <marek.va...@gmail.com> Cc: Richard Weinberger <rich...@nod.at> Cc: Cyrille Pitchen <cyrille.pitc...@wedev4u.fr> Cc: Rob Herring <robh...@kernel.org> Cc: Mark Rutland <mark.rutl...@arm.com> Signed-off-by: Tom Rini <tr...@konsulko.com> --- I have submitted a separate patch that correct the dm816x.dtsi to set the compatible string there for the elm from ti,816-elm to ti,am3352-elm and tested it on the hardware, where it works. It is quite likely that dm814x.dtsi can be trivially corrected as it came after dm816x and before am335x but as I cannot test the hardware, I did not update that. --- Documentation/devicetree/bindings/mtd/elm.txt | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/Documentation/devicetree/bindings/mtd/elm.txt b/Documentation/devicetree/bindings/mtd/elm.txt index 8c1528c421d4..59ddc61c1076 100644 --- a/Documentation/devicetree/bindings/mtd/elm.txt +++ b/Documentation/devicetree/bindings/mtd/elm.txt @@ -1,7 +1,7 @@ Error location module Required properties: -- compatible: Must be "ti,am33xx-elm" +- compatible: Must be "ti,am3352-elm" - reg: physical base address and size of the registers map. - interrupts: Interrupt number for the elm. -- 1.9.1