On Mon, Jun 12, 2017 at 05:38:56PM +0100, Mark Brown wrote: > On Mon, Jun 12, 2017 at 04:17:52PM +0100, Charles Keepax wrote: > > > r = regulator_lookup_by_name(supply); > > - if (r) > > - return r; > > Why have you left the lookup here?
Yeah was thinking that could maybe use a comment, if we don't find a match in the following loop over the supply map then we will exit with the regulator found here. So we can still use the regulator name for lookup just we default to the supply map. Thanks, Charles