On 05/24/2016 07:41 PM, Javier Martinez Canillas wrote:
> The aclk333 clock needs to be ungated during the MFC power domain switch,
> so set the clock ID to allow the Exynos power domain logic to lookup this
> clock if is defined in the MFC PD device tree node.
> 
> Signed-off-by: Javier Martinez Canillas <jav...@osg.samsung.com>
> ---
> 
>  drivers/clk/samsung/clk-exynos5420.c | 2 +-
>  1 file changed, 1 insertion(+), 1 deletion(-)

Reviewed-by: Krzysztof Kozlowski <k.kozlow...@samsung.com>

Best regards,
Krzysztof