On Sunday, 21. January 2007 20:25, Paolo Ornati wrote:
> On Sun, 21 Jan 2007 11:32:02 -0600
> Robert Hancock <[EMAIL PROTECTED]> wrote:
> 
> > It looks like what you're getting is an actual NCQ write timing out. 
> > That makes the bisect result not very interesting since obviously it 
> > wouldn't have issued any NCQ writes before NCQ support was
> > implemented. Seeing as how it's also an entirely different driver I
> > imagine it's a different problem than what I've been looking at.
> > 
> > Maybe that drive just has some issues with NCQ? I would be surprised
> > at that with a Seagate though..
> 
> I don't know. It's a two years old ST380817AS.
> 
> 
> # smartctl -a -d ata /dev/sda
> 
> smartctl version 5.36 [x86_64-pc-linux-gnu] Copyright (C) 2002-6 Bruce Allen
> Home page is http://smartmontools.sourceforge.net/
> 
> === START OF INFORMATION SECTION ===
> Model Family:     Seagate Barracuda 7200.7 and 7200.7 Plus family
> Device Model:     ST380817AS
> Serial Number:    4MR08EK8
> Firmware Version: 3.42
> User Capacity:    80,026,361,856 bytes
> Device is:        In smartctl database [for details use: -P show]
> ATA Version is:   6
> ATA Standard is:  ATA/ATAPI-6 T13 1410D revision 2
> Local Time is:    Sun Jan 21 20:15:40 2007 CET
> SMART support is: Available - device has SMART capability.
> SMART support is: Enabled
> 
> === START OF READ SMART DATA SECTION ===
> SMART overall-health self-assessment test result: PASSED
> 
> General SMART Values:
> Offline data collection status:  (0x82)       Offline data collection activity
>                                       was completed without error.
>                                       Auto Offline Data Collection: Enabled.
> Self-test execution status:      (   0)       The previous self-test routine 
> completed
>                                       without error or no self-test has ever 
>                                       been run.
> Total time to complete Offline 
> data collection:               ( 430) seconds.
> Offline data collection
> capabilities:                          (0x5b) SMART execute Offline immediate.
>                                       Auto Offline data collection on/off 
> support.
>                                       Suspend Offline collection upon new
>                                       command.
>                                       Offline surface scan supported.
>                                       Self-test supported.
>                                       No Conveyance Self-test supported.
>                                       Selective Self-test supported.
> SMART capabilities:            (0x0003)       Saves SMART data before entering
>                                       power-saving mode.
>                                       Supports SMART auto save timer.
> Error logging capability:        (0x01)       Error logging supported.
>                                       No General Purpose Logging support.
> Short self-test routine 
> recommended polling time:      (   1) minutes.
> Extended self-test routine
> recommended polling time:      (  47) minutes.
> 
> SMART Attributes Data Structure revision number: 10
> Vendor Specific SMART Attributes with Thresholds:
> ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
> WHEN_FAILED RAW_VALUE
>   1 Raw_Read_Error_Rate     0x000f   059   049   006    Pre-fail  Always      
>  -       215927244
>   3 Spin_Up_Time            0x0003   098   098   000    Pre-fail  Always      
>  -       0
>   4 Start_Stop_Count        0x0032   098   098   020    Old_age   Always      
>  -       2182
>   5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail  Always      
>  -       0
>   7 Seek_Error_Rate         0x000f   083   060   030    Pre-fail  Always      
>  -       204305750
>   9 Power_On_Hours          0x0032   097   097   000    Old_age   Always      
>  -       3494
>  10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always      
>  -       0
>  12 Power_Cycle_Count       0x0032   098   098   020    Old_age   Always      
>  -       2541
> 194 Temperature_Celsius     0x0022   024   040   000    Old_age   Always      
>  -       24 (Lifetime Min/Max 0/15)
> 195 Hardware_ECC_Recovered  0x001a   059   049   000    Old_age   Always      
>  -       215927244
> 197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always      
>  -       1
> 198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline     
>  -       1
> 199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always      
>  -       0
> 200 Multi_Zone_Error_Rate   0x0000   100   253   000    Old_age   Offline     
>  -       0
> 202 TA_Increase_Count       0x0032   100   253   000    Old_age   Always      
>  -       0
> 
> SMART Error Log Version: 1
> ATA Error Count: 12 (device log contains only the most recent five errors)
>       CR = Command Register [HEX]
>       FR = Features Register [HEX]
>       SC = Sector Count Register [HEX]
>       SN = Sector Number Register [HEX]
>       CL = Cylinder Low Register [HEX]
>       CH = Cylinder High Register [HEX]
>       DH = Device/Head Register [HEX]
>       DC = Device Command Register [HEX]
>       ER = Error register [HEX]
>       ST = Status register [HEX]
> Powered_Up_Time is measured from power on, and printed as
> DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
> SS=sec, and sss=millisec. It "wraps" after 49.710 days.
> 
> Error 12 occurred at disk power-on lifetime: 2516 hours (104 days + 20 hours)
>   When the command that caused the error occurred, the device was active or 
> idle.
> 
>   After command completion occurred, registers were:
>   ER ST SC SN CL CH DH
>   -- -- -- -- -- -- --
>   40 51 0d 5b 9d 34 e1  Error: UNC 13 sectors at LBA = 0x01349d5b = 20225371
> 
>   Commands leading to the command that caused the error were:
>   CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
>   -- -- -- -- -- -- -- --  ----------------  --------------------
>   c8 00 00 4e 9d 34 e1 00      00:03:03.851  READ DMA
>   c8 00 00 4e 9d 34 e1 00      00:03:03.848  READ DMA
>   c8 00 00 4e 9d 34 e1 00      00:03:03.846  READ DMA
>   c8 00 00 4e 9d 34 e1 00      00:03:03.843  READ DMA
>   c8 00 00 4e 9d 34 e1 00      00:03:03.839  READ DMA
> 
> Error 11 occurred at disk power-on lifetime: 2516 hours (104 days + 20 hours)
>   When the command that caused the error occurred, the device was active or 
> idle.
> 
>   After command completion occurred, registers were:
>   ER ST SC SN CL CH DH
>   -- -- -- -- -- -- --
>   40 51 0d 5b 9d 34 e1  Error: UNC 13 sectors at LBA = 0x01349d5b = 20225371
> 
>   Commands leading to the command that caused the error were:
>   CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
>   -- -- -- -- -- -- -- --  ----------------  --------------------
>   c8 00 00 4e 9d 34 e1 00      00:03:03.851  READ DMA
>   c8 00 00 4e 9d 34 e1 00      00:03:03.848  READ DMA
>   c8 00 00 4e 9d 34 e1 00      00:03:03.846  READ DMA
>   c8 00 00 4e 9d 34 e1 00      00:03:03.843  READ DMA
>   c8 00 00 4e 9d 34 e1 00      00:03:03.839  READ DMA
> 
> Error 10 occurred at disk power-on lifetime: 2516 hours (104 days + 20 hours)
>   When the command that caused the error occurred, the device was active or 
> idle.
> 
>   After command completion occurred, registers were:
>   ER ST SC SN CL CH DH
>   -- -- -- -- -- -- --
>   40 51 0d 5b 9d 34 e1  Error: UNC 13 sectors at LBA = 0x01349d5b = 20225371
> 
>   Commands leading to the command that caused the error were:
>   CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
>   -- -- -- -- -- -- -- --  ----------------  --------------------
>   c8 00 00 4e 9d 34 e1 00      00:03:03.851  READ DMA
>   c8 00 00 4e 9d 34 e1 00      00:03:03.848  READ DMA
>   c8 00 00 4e 9d 34 e1 00      00:03:03.846  READ DMA
>   c8 00 00 4e 9d 34 e1 00      00:03:03.843  READ DMA
>   c8 00 00 16 9c 34 e1 00      00:03:03.839  READ DMA
> 
> Error 9 occurred at disk power-on lifetime: 2516 hours (104 days + 20 hours)
>   When the command that caused the error occurred, the device was active or 
> idle.
> 
>   After command completion occurred, registers were:
>   ER ST SC SN CL CH DH
>   -- -- -- -- -- -- --
>   40 51 0d 5b 9d 34 e1  Error: UNC 13 sectors at LBA = 0x01349d5b = 20225371
> 
>   Commands leading to the command that caused the error were:
>   CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
>   -- -- -- -- -- -- -- --  ----------------  --------------------
>   c8 00 00 4e 9d 34 e1 00      00:03:03.851  READ DMA
>   c8 00 00 4e 9d 34 e1 00      00:03:03.848  READ DMA
>   c8 00 00 4e 9d 34 e1 00      00:03:03.846  READ DMA
>   c8 00 00 16 9c 34 e1 00      00:03:03.843  READ DMA
>   c8 00 00 0e 9b 34 e1 00      00:03:03.839  READ DMA
> 
> Error 8 occurred at disk power-on lifetime: 2516 hours (104 days + 20 hours)
>   When the command that caused the error occurred, the device was active or 
> idle.
> 
>   After command completion occurred, registers were:
>   ER ST SC SN CL CH DH
>   -- -- -- -- -- -- --
>   40 51 0d 5b 9d 34 e1  Error: UNC 13 sectors at LBA = 0x01349d5b = 20225371
> 
>   Commands leading to the command that caused the error were:
>   CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
>   -- -- -- -- -- -- -- --  ----------------  --------------------
>   c8 00 00 4e 9d 34 e1 00      00:03:03.851  READ DMA
>   c8 00 00 4e 9d 34 e1 00      00:03:03.848  READ DMA
>   c8 00 00 16 9c 34 e1 00      00:03:03.846  READ DMA
>   c8 00 00 0e 9b 34 e1 00      00:03:03.843  READ DMA
>   c8 00 00 8e 99 34 e1 00      00:03:03.839  READ DMA
> 
> SMART Self-test log structure revision number 1
> No self-tests have been logged.  [To run self-tests, use: smartctl -t]
> 
> 
> SMART Selective self-test log data structure revision number 1
>  SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
>     1        0        0  Not_testing
>     2        0        0  Not_testing
>     3        0        0  Not_testing
>     4        0        0  Not_testing
>     5        0        0  Not_testing
> Selective self-test flags (0x0):
>   After scanning selected spans, do NOT read-scan remainder of disk.
> If Selective self-test is pending on power-up, resume after 0 minute delay.
> 
(Added myself to CC.) 

>   7 Seek_Error_Rate         0x000f   083   060   030    Pre-fail  Always      
>  -       204305750
>   1 Raw_Read_Error_Rate     0x000f   059   049   006    Pre-fail  Always      
>  -       215927244
> 195 Hardware_ECC_Recovered  0x001a   059   049   000    Old_age   Always      
>  -       215927244 

Wow! that HDD is really in a bad condition.

Thanks,
        Chr.
-
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to [EMAIL PROTECTED]
More majordomo info at  http://vger.kernel.org/majordomo-info.html
Please read the FAQ at  http://www.tux.org/lkml/

Reply via email to