In order to conserve battery energy, during the PS operation,
it is expected that the supply for the battery-powered domain
to be switched from the battery (VCC_PSBATT) to (VCC_PSAUX) and
automatically be switched back to battery when VCC_PSAUX voltage
drops below a limit, doing so prevents the logic within
the battery-powered domain from functioning incorrectly.

This patch enables that feature.

Signed-off-by: Anurag Kumar Vulisha <anura...@xilinx.com>
---
 drivers/rtc/rtc-zynqmp.c | 8 ++++++++
 1 file changed, 8 insertions(+)

diff --git a/drivers/rtc/rtc-zynqmp.c b/drivers/rtc/rtc-zynqmp.c
index 8b28762..6adb603 100644
--- a/drivers/rtc/rtc-zynqmp.c
+++ b/drivers/rtc/rtc-zynqmp.c
@@ -45,6 +45,7 @@
 #define RTC_INT_SEC            BIT(0)
 #define RTC_INT_ALRM           BIT(1)
 #define RTC_OSC_EN             BIT(24)
+#define RTC_BATT_EN            BIT(31)
 
 #define RTC_CALIB_DEF          0x198233
 #define RTC_CALIB_MASK         0x1FFFFF
@@ -122,6 +123,13 @@ static int xlnx_rtc_set_alarm(struct device *dev, struct 
rtc_wkalrm *alrm)
 
 static void xlnx_init_rtc(struct xlnx_rtc_dev *xrtcdev, u32 calibval)
 {
+       u32 rtc_ctrl;
+
+       /* Enable RTC switch to battery when VCC_PSAUX is not available */
+       rtc_ctrl = readl(xrtcdev->reg_base + RTC_CTRL);
+       rtc_ctrl |= RTC_BATT_EN;
+       writel(rtc_ctrl, xrtcdev->reg_base + RTC_CTRL);
+
        /*
         * Based on crystal freq of 33.330 KHz
         * set the seconds counter and enable, set fractions counter
-- 
2.1.2