* Franklin S Cooper Jr. <fcoo...@ti.com> [160317 08:55]:
> 
> 
> On 03/17/2016 10:11 AM, Rob Herring wrote:
> > On Mon, Mar 07, 2016 at 07:23:44PM -0600, Franklin S Cooper Jr wrote:
> >> From: Vignesh R <vigne...@ti.com>
> >>
> >> Add PWMSS device tree nodes for DRA7 SoC family and add documentation
> >> for dt bindings.
> >>
> >> Signed-off-by: Vignesh R <vigne...@ti.com>
> >> [fcoo...@ti.com: Add eCAP and use updated bindings for PWMSS and ePWM]
> >> Signed-off-by: Franklin S Cooper Jr <fcoo...@ti.com>
> >> ---
> >> Version 5 changes:
> >> Add DT node for eCAP and update eCAP binding documentation
> >>
> >> Version 4 changes:
> >> Updated link to the latest documentation
> >>
> >>  .../devicetree/bindings/pwm/pwm-tiecap.txt         |  9 +++
> >>  .../devicetree/bindings/pwm/pwm-tiehrpwm.txt       |  9 +++
> >>  .../devicetree/bindings/pwm/pwm-tipwmss.txt        | 15 +++-
> >>  arch/arm/boot/dts/dra7.dtsi                        | 84 
> >> ++++++++++++++++++++++
> >>  4 files changed, 116 insertions(+), 1 deletion(-)
> >
> >> +                  ehrpwm1: pwm@48440200 {
> >> +                          compatible = "ti,dra7xx-ehrpwm",
> >> +                                       "ti,am33xx-ehrpwm";
> >> +                          #pwm-cells = <3>;
> >> +                          reg = <0x48440200 0x80>;
> >> +                          clocks = <&ehrpwm1_tbclk>;
> >> +                          clock-names = "tbclk";
> >> +                          status = "disabled";
> >> +                  };
> >> +
> >> +                  ecap1: ecap@48440100 {
> > This also is a PWM? Then it should also be pwm@...
> 
> The enhanced capture module primary purpose is to measure
> time between external signals which is called capture mode.
> It also has a PWM mode. So I wouldn't recommend generalizing
> the entire node to pwm.

So is this patch safe for me to apply now or do we need more
changes?

Regards,

Tony

Reply via email to