When machine constraints are applied, regulator framework first sets
initial mode (if any) and then enables the regulator if needed. The current
code in twl4030reg_set_mode always checks if the regulator is enabled
before applying the mode. That results in -EACCES error returned for
"always-on" regulators which have "initial-mode" set in the board DTS. Fix
that by removing the unneeded check.

Signed-off-by: Ivaylo Dimitrov <ivo.g.dimitrov...@gmail.com>
---
 drivers/regulator/twl-regulator.c | 8 --------
 1 file changed, 8 deletions(-)

diff --git a/drivers/regulator/twl-regulator.c 
b/drivers/regulator/twl-regulator.c
index be8d05e..d8f6ad6 100644
--- a/drivers/regulator/twl-regulator.c
+++ b/drivers/regulator/twl-regulator.c
@@ -371,7 +371,6 @@ static int twl4030reg_set_mode(struct regulator_dev *rdev, 
unsigned mode)
 {
        struct twlreg_info      *info = rdev_get_drvdata(rdev);
        unsigned                message;
-       int                     status;
 
        /* We can only set the mode through state machine commands... */
        switch (mode) {
@@ -385,13 +384,6 @@ static int twl4030reg_set_mode(struct regulator_dev *rdev, 
unsigned mode)
                return -EINVAL;
        }
 
-       /* Ensure the resource is associated with some group */
-       status = twlreg_grp(rdev);
-       if (status < 0)
-               return status;
-       if (!(status & (P3_GRP_4030 | P2_GRP_4030 | P1_GRP_4030)))
-               return -EACCES;
-
        return twl4030_send_pb_msg(message);
 }
 
-- 
1.9.1