Ely Levy wrote:
> 
> ---------- Forwarded message ----------
> From: niki eckstein <[EMAIL PROTECTED]>
> 
> We have a win95 client served ppp via direct cable connect and NATed
> to a cisco 2511.
> The ppp won't work at full speed (115200) but slower (90000)
> >From time to time the communication stops for a second or two and
> occasionally the communication stops completely.
> We tried to replace hard disk and hardware.

FLOW CONTROL!!!!!!!!!

1. Get a null modem cable that supports flow control
        rd -> sd
        sd -> rd
        dtr -> cd
        cd  -> dtr
        rts -> cts
        cts -> rts
        ground(7) -> ground(7)
        ground(1) -> ground(1)

2.      Set clients to use hardware flow control (crtscts).

3.      Make sure the UARTs (serial chips) are 16550afn or equivalent
        and the maxium (15) dytes are buffered.

Geoff.

-- 
Geoffrey S. Mendelson
Tel:  (03) 6944-211  Fax: (03) 6944-225 Email: [EMAIL PROTECTED] 


=================================================================
To unsubscribe, send mail to [EMAIL PROTECTED] with
the word "unsubscribe" in the message body, e.g., run the command
echo unsubscribe | mail [EMAIL PROTECTED]