Also seen in logs with the pacemaker 1.1.5: the point was unequal MTU settings between the servers ;-) After setting the same MTU on both NICs, all was working like a charm!
Have a nice day! Nikita Michalko Am Mittwoch, 5. Juni 2013 14:25:19 schrieb Ulrich Windl: > Hi! > > When the cluster (SLES11 SP2, current) was put in maintenance mode, two > messages repeat periodically, filling the log: ERROR: crm_timer_popped: > Election Timeout (I_ELECTION_DC) just popped in state S_RELEASE_DC! > (120000ms) WARN: do_log: FSA: Input I_ELECTION_DC from crm_timer_popped() > received in state S_RELEASE_DC > > crmd: [7285]: info: handle_request: Current ping state: S_RELEASE_DC > > Is this expected, or is it yet another bug (pacemaker-1.1.7-0.13.9)? > > Regards, > Ulrich > > > _______________________________________________ > Linux-HA mailing list > [email protected] > http://lists.linux-ha.org/mailman/listinfo/linux-ha > See also: http://linux-ha.org/ReportingProblems > _______________________________________________ Linux-HA mailing list [email protected] http://lists.linux-ha.org/mailman/listinfo/linux-ha See also: http://linux-ha.org/ReportingProblems
