Hey there, I think I do have a valid v2-Configuration now. I got the python-script running, with adding the variables manually. I don't understand everything in the CIB, but I think it works. ;)
Now I want to specify ONE ping node. (the switch, where both nodes are plugged in) to check if the line between the switch an the nodes are OK or not. I think I have to configure this using a pingd-clone and a constraint?!? The clone will run on both nodes and when one node will lose the connection to the switch, all resources will be switched to the other node. If both nodes don't have connection to the switch, the resources don't need to switch. Is this possible with this snippets, I copied from http://linux-ha.org/v2/faq/pingd?highlight=%28v2/faq/%29 <clone id="pingd-clone"> <meta_attributes id="pingd-clone-ma"> <attributes> <nvpair id="pingd-clone-1" name="globally_unique" value="false"/> </attributes> </meta_attributes> <primitive id="pingd-child" provider="heartbeat" class="ocf" type="pingd"> <operations> <op id="pingd-child-monitor" name="monitor" interval="20s" timeout="60s" prereq="nothing"/> <op id="pingd-child-start" name="start" prereq="nothing"/> </operations> <instance_attributes id="pingd_inst_attr"> <attributes> <nvpair id="pingd-1" name="dampen" value="5s"/> <nvpair id="pingd-2" name="multiplier" value="100"/> </attributes> </instance_attributes> </primitive> </clone> and <rsc_location id="my_resource:connected" rsc="my_resource"> <rule id="my_resource:connected:rule" score_attribute="default_ping_set"> <expression id="my_resource:connected:expr:defined" attribute="default_ping_set" operation="defined"/> </rule> </rsc_location> Are this the right snippets for this purpose? Next question: The haresources2cib.py-script created the following lines at each of my resources <op id="Filesystem_3_mon" interval="120s" name="monitor" timeout="60s"/> Does this mean, that the status of the Filesystem gets monitored? If somebody will unmount the filesystem by hand, will in the worst case be discovered after the interval of 120 seconds and then Heartbeat will try to mount it again. If this failes it will switch the resources to the second node after the timeout of 60 seconds?!? One more question: How to update the CIB? I read somewhere not to manipulate the cib.xml with an editor. But I didn't find a way to add the lines ((e.g for the clone above) with one of the tools. Is there a tool or do I have to edit it manually? So far....further questions will follow soon :P Tanks for answering Florian _______________________________________________ Linux-HA mailing list [email protected] http://lists.linux-ha.org/mailman/listinfo/linux-ha See also: http://linux-ha.org/ReportingProblems