Prezados  Colegas,

estou tentando fazer o upgrade para CL8 em um notebook com placa de rede/modem
pcmcia Megahertz. Quando instalei o CL7 nele gerei o disquete com a imagem
bootpcmcia.img, dei boot e especifiquei o diret�rio conectiva via nfs. Funciona 
muito bem. Por�m quando usei o bootpcmcia do CL8 eu n�o tive sucesso.
Investigando, resolvi comparar o syslog dos dois quando dou boot na 
op��o rescue. 
Vejam o /var/run/syslog do bootpcmcia do CL7:
<30>May 17 21:58:06 cardmgr[14]: starting, version is 3.1.10
<30>May 17 21:58:06 cardmgr[14]: watching 2 sockets
<30>May 17 21:58:06 cardmgr[14]: Card Services release does not match!
<30>May 17 21:58:07 cardmgr[14]: initializing socket 0
<6>cs: memory probe 0xa0000000-0xa0ffffff: clean.
<30>May 17 21:58:07 cardmgr[14]: socket 0: Megahertz CC/XJEM3288 Ethernet/Modem
<30>May 17 21:58:07 cardmgr[14]: executing: 'modprobe smc91c92_cs.o'
<30>May 17 21:58:08 cardmgr[14]: executing: 'modprobe serial_cs.o'

agora do CL8
<30>May 17 21:49:14 cardmgr[14]: starting, version is 3.1.10
<30>May 17 21:49:14 cardmgr[14]: watching 2 sockets
<30>May 17 21:49:14 cardmgr[14]: Card Services release does not match!
<30>May 17 21:49:14 cardmgr[14]: initializing socket 0
<30>May 17 21:49:14 cardmgr[14]: socket 0: Megahertz CC/XJEM3288 Ethernet/Modem
<30>May 17 21:49:14 cardmgr[14]: executing: 'modprobe smc91c92_cs.o'
<30>May 17 21:49:15 cardmgr[14]: modprobe exited with status 1
<30>May 17 21:49:17 cardmgr[14]: get dev info on socket 0 failed: Resource temporarily 
unavailable
<30>May 17 21:49:17 cardmgr[14]: exiting

finalmente verifiquei o que eu obtinha com lsmod:
CL7:
Module                  Size  Used by
vfat                    9284   0  (unused)
fat                    30592   0  [vfat]
serial_cs               5168   0  (unused)
smc91c92_cs            15152   0  (unused)
ds                      6124   0  [serial_cs smc91c92_cs]
i82365                 21700   2
pcmcia_core            44192   0  [serial_cs smc91c92_cs ds i82365]

CL8:
Module                  Size  Used by    Not tainted
vfat                    9096   0  (unused)
fat                    29336   0  [vfat]
serial_cs               4532   0  (unused)
ds                      6508   0  [serial_cs]
yenta_socket            7980   2
pcmcia_core            38848   0  [serial_cs ds yenta_socket]

V�-se pelo syslog que n�o consigo levantar o driver smc91c92_cs da placa de rede.
A quest�o �: proque n�o? Ser� a quest�o da troca do  i82365 pelo yenta_socket, 
entre o kernel 2.4.5 e 2.4.18? Esse problema � conhecido?

Eu poderia tentar fazer a instala��o do CL8 usando o bootpcmcia do CL7, provavelmente 
daria certo. Mas eu temo em n�o conseguir usar a placa de rede depois pelos mesmos 
motivos.

Se algu�m tiver alguma id�ia eu agade�o. Qualquer sugest�o � bem vinda.

abra�os a todos

Gerald Weber
[EMAIL PROTECTED]



Assinantes em 17/05/2002: 2253
Mensagens recebidas desde 07/01/1999: 167241
Historico e [des]cadastramento: http://linux-br.conectiva.com.br
Assuntos administrativos e problemas com a lista: 
            mailto:[EMAIL PROTECTED]

Responder a