On Thu, 2012-07-19 at 19:44 +0100, Paul Larson wrote:
>         So, click "Capture options" button (the cogwheel like icon,
>         the middle
>         one of three) and make sure that the "Energy Capture" input
>         contains
>                 <DS-5-path>/bin/caiman -d /dev/ttyACM0
> I have 5.10 (build 1389)
> I tried putting this in the energy capture field:
> /usr/local/DS-5/bin/caiman -d /dev/ttyACM0
> (I also see /usr/local/DS-5/sw/energy_probe/caiman, but the one
> in /usr/local/DS-5/bin seems to be the script that sets things up for
> it and calls the latter)

Ok, last thing to check would be the /dev/ttyACM0 permissions... Can you
actually do "cat /dev/ttyACM0"? It's a serial device, so on Ubuntu it
will be owned by "dialout" group.

> Also, fwiw, I tried running caiman from the command line, even with
> specifying -d /dev/ttyACM0 and I get no output.  Not sure if I'm
> supposed to get anything though.  All it does is create an empty file
> called "0000000000"

Yeah, it doesn't actually start talking to the probe before Streamline
connects to it...

Paweł



_______________________________________________
linaro-dev mailing list
linaro-dev@lists.linaro.org
http://lists.linaro.org/mailman/listinfo/linaro-dev

Reply via email to