On 10/27/2010 05:36 PM, shawn....@freescale.com wrote:
> From: Shawn Guo <shawn....@gmail.com>
> 
> The mx51evk u-boot has an issue that system will get reset
> every 2 hours.
> 
> MC13892 has an inside charge timer which expires in 120 minutes.
> If ICHRG and CHGAUTOB are not set properly, this timer expiration
> will get system power recycled.
> 
> Since mx51evk has no Li-Ion battery on board, the patch sets
> ICHRG in externally powered mode and sets CHGAUTOB bit to avoid
> automatic charging, so that system will not get reset by this
> timer expiration.
> 
> The patch also corrects the bit field definition of register 48
> (Charger 0) per latest MC13892 Reference Manual.
> 
> Signed-off-by: Shawn Guo <shawn....@gmail.com>

Applied to u-boot-imx, thanks.

Best regards,
Stefano Babic

-- 
=====================================================================
DENX Software Engineering GmbH,     MD: Wolfgang Denk & Detlev Zundel
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: +49-8142-66989-0 Fax: +49-8142-66989-80  Email: off...@denx.de
=====================================================================