Erik Sandberg schreef:
Hi,

I'm now changing the initialisation of now_mom and prev_mom to -inf. This has lead to the discovery of a small bug: Paper_column_engraver::make_columns () is called when the Score context is created, and it timestamps itself with an uninitialised now_mom. I suspect this means that the spacing of the first system is slightly displaced when a piece starts with a grace note. I need to fix this bug before I can go on with my work, but I know too little about paper columns to know what the proper solution is. Any ideas?

Yes, you could try delaying the setting of 'when to stop_translation_timestep.


--

Han-Wen Nienhuys - [EMAIL PROTECTED] - http://www.xs4all.nl/~hanwen

LilyPond Software Design
 -- Code for Music Notation
http://www.lilypond-design.com



_______________________________________________
lilypond-devel mailing list
lilypond-devel@gnu.org
http://lists.gnu.org/mailman/listinfo/lilypond-devel

Reply via email to