I would say that the timer granularity and the fix are two different things, even if granularity would be finer, the checking condition like before was wrong and would lead to unnecessary busy cycles. Is a timeout of only one second a real use case? In any way, your example below would result in a returned timeout value of 1000ms, so you would sleep 1s into the external poll, before calling MHD_run() again. So, in fact it would be closed at 51.999. However, yes - when a new event would come in shortly after 50.999 this would trigger the connection close earlier. --Alex
The report itself is correct, thanks for this! However while the patch fixed one problem, it creates another one. The problem connected to low granularity (rounded to one second) of the MHD's internal timer. If connection timeout is set to one second (for example) then connection may expire at any moment up to one second with the patch applied. A full example: if activity is recorded at 50.999 seconds, which is rounded to 50 internally, then connection with 1 second timeout can be closed at 51.0, which is not what is expected by user. The proper solution would be increase of the resolution of the internal MHD timer. I'll handle it. -- Evgeny On 11.08.2021 23:39, Christian Grothoff wrote: > Thanks for the detailed report, the patch looks good as-is, applied to > master as > > f5d387df7e7fb8de1a5dd0739ddb83a8b19fe64b > > Happy hacking! > > Christian > > On 8/11/21 6:02 PM, Irion, Alexander wrote: >> Hello! >> >> I discovered a problem with closing connections, when >> MHD_OPTION_CONNECTION_TIMEOUT is used. When I set the timeout option to >> 3 seconds and connect with a browser, I get a timeout value from >> MHD_get_timeout() of 3000 ms returned. I then sleep the desired time and >> call MHD_run again(). Then, MHD_get_timeout() returns repetitive a >> timeout of 0 which causes thousands of calls to MHD_run(), taking up >> several hundred milliseconds and burning CPU time. >> >> I use an external event loop with MHD_DAEMON_INFO_EPOLL_FD. >> >> As reason I found that the condition timeout < >> (MHD_monotonic_sec_counter () - connection->last_activity) will not be >> true, after waiting the timeout time. The right side will be equal to >> timeout, so the connection is not closed, MHD_get_timeout() continues to >> return a timeout value of 0, and this runs repetitively in a loop for >> some thousand iterations, until the time jumps to the next second. >> >> In the attachment please find a small patch for fixing this issue. It's >> just turning the < into a <=. >> ----------------- Siemens Electronic Design Automation GmbH; Anschrift: Arnulfstraße 201, 80634 München; Gesellschaft mit beschränkter Haftung; Geschäftsführer: Thomas Heurung, Frank Thürauf; Sitz der Gesellschaft: München; Registergericht München, HRB 106955