On Tue, Oct 26, 2010 at 6:48 PM, Nick Mathewson <ni...@freehaven.net> wrote:
> People more experienced than I am about Windows can probably weigh in
> on what the right thing is here.

I think the expectation was that each DLL that uses winsock
would call WSAStartup before using it, and WSACleanup
when done.  That's safe from winsock's point of view, I believe.
***********************************************************************