When a daemon dies unexpectedly and it will not be respawned, the
pidfile needs to be removed. (halt is set as !respawn)
--- a/service/instance.c 2016-07-01 14:22:53.507113056 +0200
+++ b/service/instance.c 2016-07-01 14:24:38.541075073 +0200
@@ -513,7 +513,7 @@
uloop_timeout_cancel(&in->timeout);
if (in->halt) {
- /* no action */
+ instance_removepid(in);
} else if (in->restart) {
instance_start(in);
} else if (in->respawn) {
_______________________________________________