This patch is a follow up to commit 4cf3fd4 "add support for indicating
the boot state using three leds".

At the time of writing the patch, I wasn't aware that it's possible to
switch info failsafe after boot (factory reset).

Enabling the failsafe led without disabling the running led causes an
unexpected led colour on devices using a single multicolour led to
indicate the boot state.

Signed-off-by: Mathias Kresin <d...@kresin.me>
---
 target/linux/lantiq/base-files/etc/diag.sh | 4 ++++
 1 file changed, 4 insertions(+)

diff --git a/target/linux/lantiq/base-files/etc/diag.sh 
b/target/linux/lantiq/base-files/etc/diag.sh
index 71d6f3e..f6363b3 100644
--- a/target/linux/lantiq/base-files/etc/diag.sh
+++ b/target/linux/lantiq/base-files/etc/diag.sh
@@ -17,6 +17,10 @@ set_state() {
                ;;
        failsafe)
                status_led_off
+               [ -n "$running" ] && {
+                       status_led="$running"
+                       status_led_off
+               }
                status_led="$failsafe"
                status_led_blink_failsafe
                ;;
-- 
1.9.1


_______________________________________________
Lede-dev mailing list
Lede-dev@lists.infradead.org
http://lists.infradead.org/mailman/listinfo/lede-dev