On Sun, 9 Sep 2018 20:44:34 +0000, Mark Morgan Lloyd via Lazarus <lazarus@lists.lazarus-ide.org> wrote:
>I did quite lot of work on the serial.pp unit more recently than that >wiki page, in fact I didn't even know it existed. Please refer to the >comments in that file in the first instance. Thanks Mark, I did that too and there is stuff I don't find there, like: Read blocking? ---------------------- From interface section: { Reads a maximum of "Count" bytes of data into the specified buffer. Result: Number of bytes read. } function SerRead(Handle: TSerialHandle; var Buffer; Count: LongInt): LongInt; Does this function read whatever is in the buffer when called up to a maximum of Count, or does it actually wait until Count bytes have arrived? If it waits, for how long? Concerning the com port name for SerOpen(): { Open the serial device with the given device name, for example: \COM1, \COM2 (strictly, \\.\COM1...) for normal serial ports. ISDN devices, serial port redirectors/virtualisers etc. normally implement names of this form, but refer to your OS documentation. Returns "0" if device could not be found } function SerOpen(const DeviceName: String): TSerialHandle; In the Wiki example they use COMx: where x is a number, but this is probably only working for single digit numbers 1..9. In any case the naming there is not described in serial.pp I need to huse a high numbered com port since all I have is USB2Serial dongles, which typically get you a port number like 29... -- Bo Berglund Developer in Sweden -- _______________________________________________ Lazarus mailing list Lazarus@lists.lazarus-ide.org https://lists.lazarus-ide.org/listinfo/lazarus