We have a third party ActiveX executable that refuses to shut itself
down once in a while.  And when I say once in a while, I mean one out
of every 20-30 times it's attempted.  All termination commands are
being sent and recieved properly, and all refnums are being closed.
No errors are ever generated, all operations report successful, but
the thing just won't die.  Problem is of course, that if we attempt to
restart our software after the ActiveX app fails to terminate, it
generates server execution errors when trying to open a new instance.
We are not expecting a speedy resolution from the third party, but it
is becoming a great inconvenience for our customers.  I would like to
be able to kill the process through the OS as a last resort.  Problem
is, to do that I need a ProcID. Is there any way to retrieve a ProcID
for the ActiveX server through LabVIEW?  Alternatives and suggestions
are welcome.

Reply via email to