Nick Miller wrote: >Does anyone have suggestions on how to eliminate or reduce the >non-simultaneous ringing of extensions on incoming calls? > >This really generates customer complaints in residential applications >where the all COs typically ring at all extensions, particularly when they >previously had an older 616 or 1232 system that didnt function that way. > > >Thanks, Nick Miller Strategic Home Media > > >_________________________________________________________________ >KX-T Mailing list --- http://kxthelp.com/ >Subscription changes: http://kxthelp.com/mailman/listinfo/kxt > > > > > if its a t816 t1232 d816 t1233, the ring is 4 groups per ring cycle. group 1 rings, then gr 2, then gr 3, then gr 4. then is starts again back at gr 1.
so, port 01,05,09,13,17 ring together, then port 02,06,10,14 ring, then 03,07,11,15 get the idea? put gr 1 phones down stairs, gr 3 up stairs, you hear downstirs ph, silence then upstairs, slience then downstairs. good luck -larry _________________________________________________________________ KX-T Mailing list --- http://kxthelp.com/ Subscription changes: http://kxthelp.com/mailman/listinfo/kxt