Randy, Somewhere in the 990 program, there is a section to define if a "flash" provides and disconnect or an EFA to the central office. Sounds as though you have disconnect activated and EFA needs to be turned on. Dont remember what line, so you may need to do a search through the 990 program, but it is there. Carmen -----Original Message----- From: [EMAIL PROTECTED] To: kxt@kxthelp.com Sent: Tue, 11 Oct 2005 11:01:43 -0700 Subject: KX-T: 816 dropping call
I have a problem that I hope the gurus of this list can help me with. I have an KX-TD816 that drops calls when flashing over to the second call on the same line. Flash time was set at 600msec and I dropped it to 300 thinking it may be too long. No difference. Any ideas? Thanks to all Randy Building 429 _________________________________________________________________ KX-T Mailing list --- http://kxthelp.com/ Subscription changes: http://kxthelp.com/mailman/listinfo/kxt _________________________________________________________________ KX-T Mailing list --- http://kxthelp.com/ Subscription changes: http://kxthelp.com/mailman/listinfo/kxt