Hi,
 
No U cant have 2 Nos TD290s in the interconected TD1232s. Max. Number of 
channels supported by TD1232 are 38.. 30 for PRI & 8 on Basic system 
configuration.
This rule also applies to E1/T1 card (TD288)
 
And no pluggable VoIP module is available.
 
Time to switch to TDA... may be? (Its confirmed 1232 discontinued in APAC)
 
Nitin

Finn Lassen <[EMAIL PROTECTED]> wrote:
Looking for phone service redundancy.

1) Is it possible to have two KX-TD290 PRI modules in a dual-cabinet
KX-TD1232-6 (one in each cabinet)?

2) Does Panasonic make a VoIP module that plugs into the KX-TD1232-6?

3) If "no" to both 1 and 2 above, I guess the solution is to get a 2, 4
or 8 port VoIP gateway and plug into the up to 8 available analog CO
lines in the master cabinet?

Finn

--