Hi, No U cant have 2 Nos TD290s in the interconected TD1232s. Max. Number of channels supported by TD1232 are 38.. 30 for PRI & 8 on Basic system configuration. This rule also applies to E1/T1 card (TD288) And no pluggable VoIP module is available. Time to switch to TDA... may be? (Its confirmed 1232 discontinued in APAC) Nitin
Finn Lassen <[EMAIL PROTECTED]> wrote: Looking for phone service redundancy. 1) Is it possible to have two KX-TD290 PRI modules in a dual-cabinet KX-TD1232-6 (one in each cabinet)? 2) Does Panasonic make a VoIP module that plugs into the KX-TD1232-6? 3) If "no" to both 1 and 2 above, I guess the solution is to get a 2, 4 or 8 port VoIP gateway and plug into the up to 8 available analog CO lines in the master cabinet? Finn -- Finn Lassen Deputy CIO Axiom 1805 Drew Street Clearwater, Florida 33765 727-442-7774 voice 727-442-8344 fax [EMAIL PROTECTED] www.axiomint.com _________________________________________________________________ KX-T Mailing list --- http://kxthelp.com/ Subscription changes: http://kxthelp.com/mailman/listinfo/kxt __________________________________________________ Do You Yahoo!? Tired of spam? Yahoo! Mail has the best spam protection around http://mail.yahoo.com _________________________________________________________________ KX-T Mailing list --- http://kxthelp.com/ Subscription changes: http://kxthelp.com/mailman/listinfo/kxt