thanks John,

i just picked up both a 160 and a 161.

i just put the 160 in the customer system to get them running.

i couldn't get the 161 to work in the shop 1985 816 (with -1 upgrade), and 
didn't try the 160. 

later, i'll play around to see what was happening, the cpu doorphone connector 
was installed "upside down"(index to 
left) at the factory, and i had to fix that first.  i need to check a few old 
816 to see if that happened before.  

all connectors index to left EXCEPT the doorphone, and the circuit board label 
shows pin 1 is 180 degrees from the 
other connectors - think the assembler just put it in backwards.  all the 
voltages are on the correct pins if i 
ignore the index.  makes me wonder how that one passed test;-)     

-larry     


6/21/05 9:28:07 AM, John Romkey <[EMAIL PROTECTED]> wrote:

>We use a 161 in a kxtd1232 that's slightly too old to support doors 3 & 
>4, and it works fine for us.
>- john romkey
>