Limit the MWL ports on the TVS to only one port (port 2).  The DBS looks for
the SAME port that lit the lamp to extinguish it.


David Pelton
Perfect Phones, Inc.
[EMAIL PROTECTED]
512-447-8886
----- Original Message ----- 
From: "Mateo Curimao" <[EMAIL PROTECTED]>
To: <[EMAIL PROTECTED]>
Sent: Thursday, February 26, 2004 11:41 AM
Subject: KX-T: Message waiting lamp keeps blinking


> Hi everybody,
>
>
>
> We have a TVS75 connected to a DBS 824 system. We have this problem on
> some of the workstation where the message waiting lamp wont turn off
> even if all messages have been deleted. But not all extension has this
> problem, only a few. Any idea on how to correct this problem?
>
>
>
> Thanks,
>
>
>
> Mat
>
>
>
>
>
>
>
>
>
> _________________________________________________________________
> KX-T Mailing list --- http://kxthelp.com/
> Subscription changes: http://kxthelp.com/mailman/listinfo/kxt
>


_________________________________________________________________
KX-T Mailing list --- http://kxthelp.com/
Subscription changes: http://kxthelp.com/mailman/listinfo/kxt

Reply via email to