Myron indicated he sent me a couple of photos.  I'll share my advise to him
with the net for any second opinions.

+++++++++++++++++++++++++++++++++++++++++

Myron,

I think I'd replace that aluminum line with a hose like the one 
running to the carb
and cover that with fire sleeve also.  I don't think the hose will 
absorb the heat
like the metal and would be much less susceptible to vibration cracking over
the long haul.  A 90 degree fitting on the top and a straight on the 
bottom would
keep it close to the firewall.  Or, maybe a 90 degree firewall fitting and then
straight ends on the hose.  Several options.  I've had two failures over the
years with metal lines forward of the firewall.  One was a primer line and
the other was a 1/8" line to the oil pressure sending unit.  I've never had
a problem with hose when they were of good quality with proper fittings.

All my lines forward of the firewall are hose with flare fittings.  I 
have a very
short line from firewall to gascolator that is not fire sleeved and still no
problems.  I do have air blast cooling on my gascolator.

Just a thought......

Larry