Ok, so I have my fuel system installed and I am wiring the pumps.  They will
have voltage all the time and the ground will be selected to each pump as it is
selected with a spdt switch.  That switch is labeled "pump 1 and pump 2".  That
ground comes from my 5psi oil switch.  So that the pump selected will only run
when the engine is running and producing oil pressure.  My second switch is to
bypass all that and provide a ground to run the pumps when priming and starting
and if the oil pressure switch was to fail.  How would you label that switch?

pump bypass
emergency pump
fuel pump on
ground use only
pump bkup power

Thanks
Craig

Reply via email to