Hi Katharina

> I guess I've made a stupid mistake and now cannot correct it.
>
> While fixing settings in the Global systems preferences under
> Administration I've changed in the 'timeout' line the '1d' to '1h',
> hoping that this will reduce the timeout from one day to one hour.
> However, it seems to have reduced it to one second! And I can do
> nothing in the system because of such short time.
> While now trying to change it back - as soon as I try to save the
> change it says, Error, change possibly not saved. I guess I'm simply
> not quick enough to do it all in one second!
> Please help me to fix it back to 1d.

I would assume you should be able to change parameter "timeout" back to the old value using this SQL statement in your database:

UPDATE systempreferences SET timeout="1d";

If you want to set timeout to one hour you probably need to change it to "3600" (meaning 3'600 seconds, the equivalent of 1 hour).

Hope this helps.

Best wishes: Michael
--
Geschäftsführer · Diplombibliothekar BBS, Informatiker eidg. Fachausweis
Admin Kuhn GmbH · Pappelstrasse 20 · 4123 Allschwil · Schweiz
T 0041 (0)61 261 55 61 · E m...@adminkuhn.ch · W www.adminkuhn.ch