Hi Russell, No worries, the change was easy. I was mostly interested in your view about the change, and you confirm the main concern is the appearance of imported schematics.
I am not sure if netlist updater is able to link a symbol and its corresponding footprint when sheetpath is not complete, but if that is the case then your other idea could be a better solution here. Best regards, Orson On 02/17/2018 12:18 AM, Russell Oliver wrote: > Hi all, > > Sorry I didn't get to it sooner. Been busy at a new job. > > I was going to say that globals will work fine except for the visual > aspect. Though I think just replacing the global net on the pcb with the > net from the schematic with the matching end label ( ignoring any sheet > path) should work too, since it will be unique anyway if importing from an > eagle schematic. > > Kind Regards > Russell > > > On 17 Feb 2018 10:06, "Maciej Suminski" <maciej.sumin...@cern.ch> wrote: > > Alright, I switched the importer to use global net labels. Perhaps > schematics are not always the prettiest ones, but at least they are > equivalent to the original project. > > Cheers, > Orson > > On 02/16/2018 02:59 PM, Wayne Stambaugh wrote: >> If using global nets resolves the issue and doesn't cause any other >> issues, it has my vote as well. >> >> On 02/16/2018 08:36 AM, Maciej Sumiński wrote: >>> I vote for switching to global nets. I may handle this, just want to be >>> sure Russell has not started already working on it, so there is no work >>> duplication. >>> >>> Regards, >>> Orson >>> >>> On 02/16/2018 02:17 PM, Wayne Stambaugh wrote: >>>> Gentlemen, >>>> >>>> What is the status of this bug fix? I know there was some discussion >>>> about this patch. Do we have path forward on this yet? I would like to >>>> get this into rc1 if possible. >>>> >>>> Thanks, >>>> >>>> Wayne >>>> On 02/14/2018 08:17 AM, Russell Oliver wrote: >>>>> Please find the attached patch for this issue. >>>>> >>>>> On Tue, Feb 13, 2018 at 2:34 AM Maciej Sumiński < > maciej.sumin...@cern.ch >>>>> <mailto:maciej.sumin...@cern.ch>> wrote: >>>>> >>>>> Hi Russell, >>>>> >>>>> On 02/11/2018 05:41 AM, Russell Oliver wrote: >>>>> > Hi All, >>>>> > >>>>> > I've discovered the cause of a problem when importing Eagle >>>>> Projects and >>>>> > getting the schematic and boards synced. >>>>> > >>>>> > Currently when importing an Eagle schematic, labels for nets that >>>>> are only >>>>> > found one Eagle sheet are imported as local KiCad labels. This >>>>> preserves >>>>> > the visual design of the schematic some what. For eagle > schematics >>>>> with >>>>> > more than 1 sheet, where hierarchical sheets are created in > Kicad, >>>>> global >>>>> > labels are created to tie the nets together across the sheets the >>>>> same as >>>>> > Eagle due to its lack of scopes for net names. >>>>> > >>>>> > The problem is that the imported PCB will have net names that are >>>>> global >>>>> > e.g "VBUS" while the imported schematic may end up with local >>>>> netname for >>>>> > the root sheet e.g "/VBUS". This will cause errors for boards > with >>>>> zones >>>>> > and named vias with the original/global netname e.g."VBUS" >>>>> > >>>>> > My proposal to fix this is to create another pass in the netlist >>>>> generation >>>>> > code that would remove the forward slash '/' for unique local > nets >>>>> in the >>>>> > root sheet provided it does not clash with an existing net name. >>>>> >>>>> Good catch. I would rather not modify the netlist generator code, > but >>>>> add another pass in the board importer. I suggest the following: >>>>> - Move netlist generation from kicad/import_project.cpp to >>>>> SCH_EDIT_FRAME::ImportFile(). >>>>> - Move netlist import from kicad/import_project.cpp to >>>>> PCB_EDIT_FRAME::ImportFile(). >>>>> - After importing a board and its netlist, go through the list of > zones >>>>> and try to assign '/' + zone->GetNetname(). If such netlist > exists, then >>>>> it means the assigned net is a local one and needs renaming. The > only >>>>> problem here is a potential conflict if there exist both 'netname' >>>>> (local label) and '/netname' (global label). I guess such case > deserves >>>>> a huge warning, so the user needs to verify the import result. >>>>> >>>>> I suppose the last special case should be simply reported by the > ERC >>>>> even without importing a project, as it creates a connection > between two >>>>> seemingly not related nets. >>>>> >>>>> Thoughts? >>>>> >>>>> Regards, >>>>> Orson >>>>> >>>>> > Kind Regards >>>>> > Russell >>>>> > >>>>> > >>>>> > P.S During debugging this issue, I discovered that a local label >>>>> and global >>>>> > label of the same name on the same sheet are connected regardless >>>>> of any >>>>> > wires. Which if there is a hierarchical sheet can lead to the > same >>>>> net for >>>>> > 2 wire segments on separate sheets connected only to local > labels, >>>>> if the >>>>> > identical global label is somewhere else on both sheets. Is this > the >>>>> > expected behaviour? or just a side effect? >>>>> > >>>>> >>>>> >>>> >>> >>> >> > _______________________________________________ Mailing list: https://launchpad.net/~kicad-developers Post to : kicad-developers@lists.launchpad.net Unsubscribe : https://launchpad.net/~kicad-developers More help : https://help.launchpad.net/ListHelp