https://bugs.kde.org/show_bug.cgi?id=496862
Bug ID: 496862 Summary: Non-floating Panel with "Fit Content" does not take the correct width on plasmashell start Classification: Plasma Product: plasmashell Version: 6.2.4 Platform: Arch Linux OS: Linux Status: REPORTED Severity: normal Priority: NOR Component: Panel Assignee: plasma-b...@kde.org Reporter: alexan...@mrfantome.fr CC: niccolo.venera...@gmail.com Target Milestone: 1.0 SUMMARY I have a panel with "icons-only task manager" that does not extend to cover all the icons at re-.start of plasmashell. STEPS TO REPRODUCE 1. Create a panel set to: - position=bottom / alignment=center / width=fit to content - visibility=auto hide / opacity=translucent / style=floating 2. Add around 10 icons 3. log out then log in OBSERVED RESULT The Panel only covers the right most icon. When entering edit mode the panel adjusts its size to cover all icons. EXPECTED RESULT The panel should cover all icons. SOFTWARE/OS VERSIONS Operating System: Arch Linux KDE Plasma Version: 6.2.4 KDE Frameworks Version: 6.8.0 Qt Version: 6.8.0 Kernel Version: 6.12.1-arch1-1 (64-bit) Graphics Platform: Wayland Processors: 16 × AMD Ryzen 7 3700X 8-Core Processor Memory: 15.5 GiB of RAM Graphics Processor: NVIDIA GeForce RTX 2070/PCIe/SSE2 ADDITIONAL INFORMATION nvidia-dkms: 565.57.01-2 -- You are receiving this mail because: You are watching all bug changes.