https://bugs.kde.org/show_bug.cgi?id=488095

--- Comment #3 from Tom Dzmelyk <tddzm...@mtu.edu> ---
Spent a couple hours this morning tracking this down. Tried a lot of dumb ideas
before I had a smart one.

Before 6.1 the plasma-pa OSD was not controlled by the global "Workspace" -> 
"General Behavior" -> "Display visual feedback for status changes" toggle. Now
in 6.1 that toggle does apply to plasma-pa's OSD.

So what probably should happen is the "Sound" -> "Configure Volume Controls" ->
"Show visual feedback" check boxes should be dimmed or otherwise indicate that
they wont apply because they are overridden by the global  "Display visual
feedback for status changes" toggle.

-- 
You are receiving this mail because:
You are watching all bug changes.